Journal article · 2020 · Open access

Consider Integration of Finger into Universal Vacuum Gripper: Performance Comparison between Soft Finger Built-in Type and Hard Finger External Type

Yusuke Nakai, Toshihiko Shimizu, Shuhei Ikemoto

The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec), 2020(0), 2A1–J12 · Published 1 January 2020 · DOI 10.1299/jsmermd.2020.2a1-j12

Open PDFView at the publisherCite this paper

In brief

“Consider Integration of Finger into Universal Vacuum Gripper: Performance Comparison between Soft Finger Built-in Type and Hard Finger External Type” is a 2020 journal article by Yusuke Nakai and 2 co-authors, published in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec). OpenAlex counts 0 citations as of 22 November 2026. It is open access: the full text is free to read at The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec).

Citations
0
Authors
3

Abstract

In this paper, two types of Universal Vacuum Chuck (in short, UVC) with a finger structure for grasping various objects are proposed. The UVC is a vacuum suction cup based on the jamming transition phenomenon, which is a combination of Universal Vacuum Gripper and robotic finger. One of UVC has a built-in soft finger, and the other type has an external hard finger. The adhesion and gripping performance of the two UVCs were evaluated. The soft finger type was suitable the low and wide uneven surface and was able to grip a small test piece. On the other hand the hard finger type was suitable high and narrow uneven surfaces and showed high gripping force.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Nakai, Y., Shimizu, T., & Ikemoto, S. (2020). Consider Integration of Finger into Universal Vacuum Gripper: Performance Comparison between Soft Finger Built-in Type and Hard Finger External Type. The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec), 2020(0), 2A1–J12. https://doi.org/10.1299/jsmermd.2020.2a1-j12

MLA 9

Nakai, Yusuke, et al. “Consider Integration of Finger into Universal Vacuum Gripper: Performance Comparison between Soft Finger Built-in Type and Hard Finger External Type.” The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec), vol. 2020, no. 0, 2020, pp. 2A1–J12. https://doi.org/10.1299/jsmermd.2020.2a1-j12.

Chicago

Nakai, Yusuke, Toshihiko Shimizu, and Shuhei Ikemoto. 2020. “Consider Integration of Finger into Universal Vacuum Gripper: Performance Comparison between Soft Finger Built-in Type and Hard Finger External Type.” The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec) 2020 (0): 2A1–J12. https://doi.org/10.1299/jsmermd.2020.2a1-j12.

Harvard

Nakai, Y., Shimizu, T. and Ikemoto, S. (2020) ‘Consider Integration of Finger into Universal Vacuum Gripper: Performance Comparison between Soft Finger Built-in Type and Hard Finger External Type’, The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec), 2020(0), pp. 2A1–J12. doi:10.1299/jsmermd.2020.2a1-j12.

IEEE

Y. Nakai, T. Shimizu, and S. Ikemoto, “Consider Integration of Finger into Universal Vacuum Gripper: Performance Comparison between Soft Finger Built-in Type and Hard Finger External Type,” The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec), vol. 2020, no. 0, pp. 2A1–J12, 2020, doi: 10.1299/jsmermd.2020.2a1-j12.

BibTeX

@article{nakai2020consider,
  title     = {{Consider Integration of Finger into Universal Vacuum Gripper: Performance Comparison between Soft Finger Built-in Type and Hard Finger External Type}},
  author    = {Nakai, Yusuke and Shimizu, Toshihiko and Ikemoto, Shuhei},
  journal   = {The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)},
  year      = {2020},
  volume    = {2020},
  number    = {0},
  pages     = {2A1--J12},
  doi       = {10.1299/jsmermd.2020.2a1-j12},
  url       = {https://doi.org/10.1299/jsmermd.2020.2a1-j12}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning

  • vacuum chuck
  • robotic fingers
  • jamming transition
  • soft fingers
  • vacuum suction cup
  • adhesion
  • gripping force
  • object grasping

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Nakai, Y., Shimizu, T., & Ikemoto, S. (2020). Consider Integration of Finger into Universal Vacuum Gripper: Performance Comparison between Soft Finger Built-in Type and Hard Finger External Type. The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec), 2020(0), 2A1–J12. https://doi.org/10.1299/jsmermd.2020.2a1-j12

How many times has this paper been cited?

0 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec): sign in and open the PDF from this page.

Who wrote this paper?

Yusuke Nakai, Toshihiko Shimizu, Shuhei Ikemoto.

What is the DOI of this paper?

10.1299/jsmermd.2020.2a1-j12, permanently at https://doi.org/10.1299/jsmermd.2020.2a1-j12. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.