Journal article · 2023 · Open access

Comparison of Ultrasonography and Cone-Beam Computed Tomography Accuracy in Measuring the Soft Tissue Thickness of Maxillary and Mandibular Gingiva in a Sheep Model

S. Latifi, Emadoddin Moudi, Farida Abesi, A. Minouei, M. Hozouri, Ali Bijani

Acta Medica Bulgarica, 50(4), 41–46 · Published 1 December 2023 · DOI 10.2478/amb-2023-0042

Open PDFView at the publisherCite this paper

In brief

“Comparison of Ultrasonography and Cone-Beam Computed Tomography Accuracy in Measuring the Soft Tissue Thickness of Maxillary and Mandibular Gingiva in a Sheep Model” is a 2023 journal article by S. Latifi and 5 co-authors, published in Acta Medica Bulgarica. OpenAlex counts 2 citations as of 18 November 2026. It is open access under a CC BY-NC-ND licence: the full text is free to read at Acta Medica Bulgarica.

Citations
2
Most cited in
2024 (1)
Field-weighted impact
0.37
References
18
Authors
6

Abstract

Background To date, few studies have compared the accuracy of cone-beam computed tomography (CBCT) and ultrasonography in measuring the soft tissue thickness of the maxillary and mandibular gingiva. Aims To compare the accuracy of ultrasonography and CBCT in measuring the soft tissue thickness of the maxillary and mandibular gingiva in a sheep model. Materials and Methods In this study, 38 different landmarks (26 points from the upper jaw and 12 points from the lower jaw) were evaluated. The gingival soft tissue thickness was measured using a digital caliper, ultrasonography, and standard and high-resolution CBCTs. The measurements were finally compared with each other. Results Regarding the thicknesses < 2 mm, no significant difference was seen between the measurements of the digital caliper and ultrasonography (mean difference < 0.1 mm, p = 0.140). Conversely, data analysis indicated significant differences between CBCTs measurements and digital caliper and ultrasonography measurements. Regarding thicknesses > 2 mm, digital caliper measurement was not significantly different from ultrasonography and high-resolution CBCT measurements (mean differences < 0.1 mm) but differed from the standard CBCT measurement. Also, a significant difference was observed between ultrasonography and standard CBCT measurements but not between ultrasonography and high-resolution CBCT (mean differences < 0.1 mm). Finally, mean differences between standard and high-resolution CBCT measurements were statistically significant. Conclusion According to the results, ultrasonography can be a reliable option for measuring gingival soft tissues regardless of their thickness, while CBCT may be more suitable for thicker gingival tissues. Clinicians should carefully consider the measurement accuracy of different imaging methods when planning dental procedures.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Latifi, S., Moudi, E., Abesi, F., Minouei, A., Hozouri, M., & Bijani, A. (2023). Comparison of Ultrasonography and Cone-Beam Computed Tomography Accuracy in Measuring the Soft Tissue Thickness of Maxillary and Mandibular Gingiva in a Sheep Model. Acta Medica Bulgarica, 50(4), 41–46. https://doi.org/10.2478/amb-2023-0042

MLA 9

Latifi, S., et al. “Comparison of Ultrasonography and Cone-Beam Computed Tomography Accuracy in Measuring the Soft Tissue Thickness of Maxillary and Mandibular Gingiva in a Sheep Model.” Acta Medica Bulgarica, vol. 50, no. 4, 2023, pp. 41–46. https://doi.org/10.2478/amb-2023-0042.

Chicago

Latifi, S., Emadoddin Moudi, Farida Abesi, A. Minouei, M. Hozouri, and Ali Bijani. 2023. “Comparison of Ultrasonography and Cone-Beam Computed Tomography Accuracy in Measuring the Soft Tissue Thickness of Maxillary and Mandibular Gingiva in a Sheep Model.” Acta Medica Bulgarica 50 (4): 41–46. https://doi.org/10.2478/amb-2023-0042.

Harvard

Latifi, S. et al. (2023) ‘Comparison of Ultrasonography and Cone-Beam Computed Tomography Accuracy in Measuring the Soft Tissue Thickness of Maxillary and Mandibular Gingiva in a Sheep Model’, Acta Medica Bulgarica, 50(4), pp. 41–46. doi:10.2478/amb-2023-0042.

IEEE

S. Latifi, E. Moudi, F. Abesi, A. Minouei, M. Hozouri, and A. Bijani, “Comparison of Ultrasonography and Cone-Beam Computed Tomography Accuracy in Measuring the Soft Tissue Thickness of Maxillary and Mandibular Gingiva in a Sheep Model,” Acta Medica Bulgarica, vol. 50, no. 4, pp. 41–46, 2023, doi: 10.2478/amb-2023-0042.

BibTeX

@article{latifi2023comparison,
  title     = {{Comparison of Ultrasonography and Cone-Beam Computed Tomography Accuracy in Measuring the Soft Tissue Thickness of Maxillary and Mandibular Gingiva in a Sheep Model}},
  author    = {Latifi, S. and Moudi, Emadoddin and Abesi, Farida and Minouei, A. and Hozouri, M. and Bijani, Ali},
  journal   = {Acta Medica Bulgarica},
  year      = {2023},
  volume    = {50},
  number    = {4},
  pages     = {41--46},
  doi       = {10.2478/amb-2023-0042},
  url       = {https://doi.org/10.2478/amb-2023-0042}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Radiography and Imaging

  • ultrasonography
  • cone-beam computed tomography
  • measurement accuracy
  • maxillary gingiva
  • mandibular gingiva
  • sheep model
  • digital caliper
  • dental imaging

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Latifi, S., Moudi, E., Abesi, F., Minouei, A., Hozouri, M., & Bijani, A. (2023). Comparison of Ultrasonography and Cone-Beam Computed Tomography Accuracy in Measuring the Soft Tissue Thickness of Maxillary and Mandibular Gingiva in a Sheep Model. Acta Medica Bulgarica, 50(4), 41–46. https://doi.org/10.2478/amb-2023-0042

How many times has this paper been cited?

2 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Acta Medica Bulgarica: sign in and open the PDF from this page.

Who wrote this paper?

S. Latifi, Emadoddin Moudi, Farida Abesi, A. Minouei, M. Hozouri, Ali Bijani.

What is the DOI of this paper?

10.2478/amb-2023-0042, permanently at https://doi.org/10.2478/amb-2023-0042. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.