Journal article · 2026 · Open access

Comparative effectiveness of three splints for rehabilitation after finger flexor tendon repair (FIRST): randomised controlled trial

Emma Bamford, Hannah Berntsson, Suzanne Beale, Freya Marks, Lauren Desoysa, Joseph J. Dias, Sienna Hamer‐Kiwacz, Charlotte Head, Daniel Hind, Nick A. Johnson, Amanda Loban, Kaye Malloy and 7 more

BMJ, 395, e100953 · Published 27 October 2026 · DOI 10.1136/bmj-2026-100953

Open PDFView at the publisherCite this paper

In brief

“Comparative effectiveness of three splints for rehabilitation after finger flexor tendon repair (FIRST): randomised controlled trial” is a 2026 journal article by Emma Bamford and 18 co-authors, published in BMJ. OpenAlex counts 1 citations as of 18 November 2026. It is open access under a CC BY licence: the full text is free to read at BMJ.

Citations
1
Most cited in
2026 (1)
Field-weighted impact
3.78
References
24
Authors
19

Abstract

OBJECTIVE: To compare the clinical effectiveness of three splints after repair of zone 1 and 2 flexor tendons: forearm based (long), Manchester short (short), and relative motion flexion (mini) splints. DESIGN: Prospective, randomised, parallel group, pragmatic, superiority, clinical trial. SETTING: 26 UK hospitals. PARTICIPANTS: 430 participants (aged ≥16 years) requiring rehabilitation after primary repair of zone 1 and 2 flexor tendons in one or two fingers of the hand according to British Society for Surgery of the Hand guidelines. INTERVENTIONS: Participants were randomly assigned 1:1:1 to the long, short, or mini splint. Splints were worn continuously for five weeks and intermittently for a further week at night and in vulnerable situations such as public environments. Masking participants was not possible owing to the nature of the intervention. MAIN OUTCOME MEASURES: The primary outcome was the mean post-randomisation score on the patient-rated wrist and hand evaluation (PRWHE) instrument at 6, 12, 26, and 52 weeks, analysed by intention to treat. RESULTS: 430 participants were randomised to the long splint (n=143), short splint (n=140), or mini splint (n=147) and 403 were included in the intention-to-treat analysis. Adherence, defined as wearing the splint for a minimum of five weeks, was 83% (118/143) for the long splint, 76% (106/140) for the short splint, and 78% (115/147) for the mini splint. Mean post-randomisation PRWHE scores were 24.5 (standard deviation 15.5) in the long splint group, 23.5 (16.7) in the short splint group, and 22.4 (15.0) in the mini splint group, with adjusted between group differences of 0.3 (98.3% confidence interval -4.0 to 4.6, P=0.88) for the long versus short splint, 2.3 (-1.9 to 6.5, P=0.19) for the long versus mini splint, and 2.0 (-2.2 to 6.3, P=0.25) for the short versus mini splint. Serious adverse event rates occurred in 10% (14/143) of participants in the long splint group, 11% (15/140) in the short splint group, and 11% (16/147) in the mini splint group. CONCLUSION: This trial found no statistically significant difference in clinical effectiveness between the long, short, and mini splint. Apart from some small differences, secondary outcomes were comparable across all three groups. TRIAL REGISTRATION: ISRCTN Registry ISRCTN10236011.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Bamford, E., Berntsson, H., Beale, S., Marks, F., Desoysa, L., Dias, J. J., Hamer‐Kiwacz, S., Head, C., Hind, D., Johnson, N. A., Loban, A., Malloy, K., Morvan, E., Rombach, I., Selby, A., Turtle, C., Walters, S., Young, T., & Drummond, A. E. (2026). Comparative effectiveness of three splints for rehabilitation after finger flexor tendon repair (FIRST): randomised controlled trial. BMJ, 395, e100953. https://doi.org/10.1136/bmj-2026-100953

MLA 9

Bamford, Emma, et al. “Comparative effectiveness of three splints for rehabilitation after finger flexor tendon repair (FIRST): randomised controlled trial.” BMJ, vol. 395, 2026, p. e100953. https://doi.org/10.1136/bmj-2026-100953.

Chicago

Bamford, Emma, Hannah Berntsson, Suzanne Beale, Freya Marks, Lauren Desoysa, Joseph J. Dias, Sienna Hamer‐Kiwacz, et al. 2026. “Comparative effectiveness of three splints for rehabilitation after finger flexor tendon repair (FIRST): randomised controlled trial.” BMJ 395: e100953. https://doi.org/10.1136/bmj-2026-100953.

Harvard

Bamford, E. et al. (2026) ‘Comparative effectiveness of three splints for rehabilitation after finger flexor tendon repair (FIRST): randomised controlled trial’, BMJ, 395, p. e100953. doi:10.1136/bmj-2026-100953.

IEEE

E. Bamford et al., “Comparative effectiveness of three splints for rehabilitation after finger flexor tendon repair (FIRST): randomised controlled trial,” BMJ, vol. 395, p. e100953, 2026, doi: 10.1136/bmj-2026-100953.

BibTeX

@article{bamford2026comparative,
  title     = {{Comparative effectiveness of three splints for rehabilitation after finger flexor tendon repair (FIRST): randomised controlled trial}},
  author    = {Bamford, Emma and Berntsson, Hannah and Beale, Suzanne and Marks, Freya and Desoysa, Lauren and Dias, Joseph J. and Hamer‐Kiwacz, Sienna and Head, Charlotte and Hind, Daniel and Johnson, Nick A. and Loban, Amanda and Malloy, Kaye and Morvan, E. and Rombach, Ines and Selby, Anna and Turtle, Chris and Walters, Stephen and Young, Tracey and Drummond, Avril ER},
  journal   = {BMJ},
  year      = {2026},
  volume    = {395},
  pages     = {e100953},
  doi       = {10.1136/bmj-2026-100953},
  url       = {https://doi.org/10.1136/bmj-2026-100953}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Health Sciences › Medicine › Surgery › Orthopedic Surgery and Rehabilitation

  • splints
  • postoperative rehabilitation
  • hand function
  • hand surgery outcomes
  • patient-reported outcomes
  • postoperative pain and swelling
  • return to work

Work with this paper

Most-cited papers in Medicine

All highly cited Medicine papers

Questions about this paper

How do I cite this paper in APA style?

Bamford, E., Berntsson, H., Beale, S., Marks, F., Desoysa, L., Dias, J. J., Hamer‐Kiwacz, S., Head, C., Hind, D., Johnson, N. A., Loban, A., Malloy, K., Morvan, E., Rombach, I., Selby, A., Turtle, C., Walters, S., Young, T., & Drummond, A. E. (2026). Comparative effectiveness of three splints for rehabilitation after finger flexor tendon repair (FIRST): randomised controlled trial. BMJ, 395, e100953. https://doi.org/10.1136/bmj-2026-100953

How many times has this paper been cited?

1 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at BMJ: sign in and open the PDF from this page.

Who wrote this paper?

Emma Bamford, Hannah Berntsson, Suzanne Beale, Freya Marks, Lauren Desoysa, Joseph J. Dias, Sienna Hamer‐Kiwacz, Charlotte Head, Daniel Hind, Nick A. Johnson, Amanda Loban, Kaye Malloy and 7 more.

What is the DOI of this paper?

10.1136/bmj-2026-100953, permanently at https://doi.org/10.1136/bmj-2026-100953. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.