Journal article · 2026 · Open access

Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial

Zhuo‐Li Huang, X J Fu, Chen Sun, Shujiao Qian, Hongchang Lai, Beilei Liu, Junyu Shi

Clinical Oral Implants Research · Published 18 November 2026 · DOI 10.1111/clr.70204

Open PDFView at the publisherCite this paper

In brief

“Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial” is a 2026 journal article by Zhuo‐Li Huang and 6 co-authors, published in Clinical Oral Implants Research. OpenAlex counts 0 citations as of 25 November 2026. It is open access: the full text is free to read at Clinical Oral Implants Research.

Citations
0
References
28
Authors
7

Abstract

OBJECTIVES: To compare the passive fit, accuracy discrepancy, patient-reported outcomes, and operator assessment between intraoral photogrammetry (IPG) and conventional impression (CI) for complete-arch implant-supported prostheses. MATERIALS AND METHODS: Patients requiring complete-arch implant-supported prostheses were recruited. Each arch received both IPG and CI and was randomly assigned to one of two groups; a titanium framework was fabricated accordingly. The primary outcome was the passive fit of the framework. Secondary outcomes included accuracy discrepancies (RMS errors, distance errors, angle errors), patient-reported outcomes, and operator assessments. RESULTS: A total of 26 arches (13 in each group) from 17 patients were included. IPG was non-inferior to CI for passive fit score (adjusted between-group difference: 95% CI, -0.74-0.55; p = 0.003), including alternate finger pressure test (0/13 vs. 0/13), Sheffield test (4/13 vs. 5/13), marginal fit with all screws tightened (1/13 vs. 0/13), panoramic radiographic assessment (4/13 vs. 2/13), and screw resistance test (1/13 vs. 2/13). The RMS error, distance deviations, and angle deviation between IPG and CI were 31.50 ± 10.36 μm, 41.90 μm (IQR: 50.00 μm), and 0.19° (IQR: 0.24°), respectively. Patients rated IPG greater comfort (p = 0.035), lower anxiety (p = 0.005), and less nausea (p = 0.017). Operators reported less interference from patient reactions (p = 0.020) and greater fluency (p = 0.035) with IPG. CONCLUSION: Within the limitations of the present study, IPG achieved non-inferior passive fit with CI with clinically acceptable accuracy, superior patient comfort, and fewer operator disturbances, supporting its use as an alternative for complete-arch implant impressions. TRIAL REGISTRATION: ClinicalTrials.gov, NCT07190820.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Huang, Z., Fu, X. J., Sun, C., Qian, S., Lai, H., Liu, B., & Shi, J. (2026). Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70204

MLA 9

Huang, Zhuo‐Li, et al. “Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial.” Clinical Oral Implants Research, 2026. https://doi.org/10.1111/clr.70204.

Chicago

Huang, Zhuo‐Li, X J Fu, Chen Sun, Shujiao Qian, Hongchang Lai, Beilei Liu, and Junyu Shi. 2026. “Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial.” Clinical Oral Implants Research. https://doi.org/10.1111/clr.70204.

Harvard

Huang, Z. et al. (2026) ‘Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial’, Clinical Oral Implants Research. doi:10.1111/clr.70204.

IEEE

Z. Huang et al., “Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial,” Clinical Oral Implants Research, 2026, doi: 10.1111/clr.70204.

BibTeX

@article{huang2026clinical,
  title     = {{Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial}},
  author    = {Huang, Zhuo‐Li and Fu, X J and Sun, Chen and Qian, Shujiao and Lai, Hongchang and Liu, Beilei and Shi, Junyu},
  journal   = {Clinical Oral Implants Research},
  year      = {2026},
  doi       = {10.1111/clr.70204},
  url       = {https://doi.org/10.1111/clr.70204}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes

  • conventional impressions
  • passive fit
  • patient comfort
  • patient-reported outcomes
  • digital dentistry
  • titanium framework

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Huang, Z., Fu, X. J., Sun, C., Qian, S., Lai, H., Liu, B., & Shi, J. (2026). Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70204

How many times has this paper been cited?

0 times, according to OpenAlex on 25 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Clinical Oral Implants Research: sign in and open the PDF from this page.

Who wrote this paper?

Zhuo‐Li Huang, X J Fu, Chen Sun, Shujiao Qian, Hongchang Lai, Beilei Liu, Junyu Shi.

What is the DOI of this paper?

10.1111/clr.70204, permanently at https://doi.org/10.1111/clr.70204. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 25 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.