Journal article · 2026 · Open access

Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study

Miguel Gómez‐Polo, Solange Vasquez-Ramos, Marta Revilla‐León, Rocío Cascos

Clinical Oral Implants Research · Published 14 October 2026 · DOI 10.1111/clr.70192

Open PDFView at the publisherCite this paper

In brief

“Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study” is a 2026 journal article by Miguel Gómez‐Polo and 3 co-authors, published in Clinical Oral Implants Research. OpenAlex counts 0 citations as of 17 November 2026. It is open access: the full text is free to read at Clinical Oral Implants Research.

Citations
0
References
31
Authors
4

Abstract

AIM: To evaluate and compare the positional accuracy of complete arch intraoral digital implant scans obtained using a conventional scan body protocol and a customized metallic ring-based calibrated framework. MATERIALS AND METHODS: A completely edentulous arch restored with six implants was scanned using two complete arch intraoral digital impression protocols: a conventional scan body protocol (SB) and a metallic ring-based calibrated framework (CF). Twenty scans were obtained per group using the same intraoral scanner. A coordinate measuring machine (CMM) dataset served as the reference standard. All STL files were imported into dental CAD software to design a standardized virtual implant-supported bar, which was subsequently analyzed using reverse engineering software. Linear inter-implant distances and angular deviations were calculated. Trueness was defined as the absolute deviation from the CMM reference, and precision as the variability among repeated scans. Between-group comparisons were performed using independent t-tests with Welch correction and Holm adjustment (α = 0.05). RESULTS: The mean linear deviation was 0.034 (0.004) mm for CF and 0.124 (0.019) mm for SB (p < 0.01). The mean angular deviation was 0.31 (0.05) degrees for CF and 0.55 (0.10) degrees for SB (p < 0.01). CONCLUSIONS: The calibrated splinting protocol showed greater trueness and lower variability compared with the conventional scan body approach.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Gómez‐Polo, M., Vasquez-Ramos, S., Revilla‐León, M., & Cascos, R. (2026). Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70192

MLA 9

Gómez‐Polo, Miguel, et al. “Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study.” Clinical Oral Implants Research, 2026. https://doi.org/10.1111/clr.70192.

Chicago

Gómez‐Polo, Miguel, Solange Vasquez-Ramos, Marta Revilla‐León, and Rocío Cascos. 2026. “Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study.” Clinical Oral Implants Research. https://doi.org/10.1111/clr.70192.

Harvard

Gómez‐Polo, M. et al. (2026) ‘Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study’, Clinical Oral Implants Research. doi:10.1111/clr.70192.

IEEE

M. Gómez‐Polo, S. Vasquez-Ramos, M. Revilla‐León, and R. Cascos, “Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study,” Clinical Oral Implants Research, 2026, doi: 10.1111/clr.70192.

BibTeX

@article{gomezpolo2026clinical,
  title     = {{Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study}},
  author    = {Gómez‐Polo, Miguel and Vasquez-Ramos, Solange and Revilla‐León, Marta and Cascos, Rocío},
  journal   = {Clinical Oral Implants Research},
  year      = {2026},
  doi       = {10.1111/clr.70192},
  url       = {https://doi.org/10.1111/clr.70192}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes

  • scanning accuracy
  • trueness and precision
  • coordinate measuring machine
  • inter-implant distance
  • angular deviation
  • edentulous arch

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Gómez‐Polo, M., Vasquez-Ramos, S., Revilla‐León, M., & Cascos, R. (2026). Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70192

How many times has this paper been cited?

0 times, according to OpenAlex on 17 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Clinical Oral Implants Research: sign in and open the PDF from this page.

Who wrote this paper?

Miguel Gómez‐Polo, Solange Vasquez-Ramos, Marta Revilla‐León, Rocío Cascos.

What is the DOI of this paper?

10.1111/clr.70192, permanently at https://doi.org/10.1111/clr.70192. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 17 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.