Review article · 2017 · Open access

Blood–brain barrier-on-a-chip: Microphysiological systems that capture the complexity of the blood–central nervous system interface

Duc T. T. Phan, R. Hugh F. Bender, Jillian W. Andrejecsk, Agua Sobrino, Stephanie J. Hachey, Steven C. George, Christopher C.W. Hughes

Experimental Biology and Medicine, 242(17), 1669–1678 · Published 14 February 2017 · DOI 10.1177/1535370217694100

Open full textView at the publisherCite this paper

In brief

“Blood–brain barrier-on-a-chip: Microphysiological systems that capture the complexity of the blood–central nervous system interface” is a 2017 review article by Duc T. T. Phan and 6 co-authors, published in Experimental Biology and Medicine. OpenAlex counts 132 citations as of 21 November 2026, which puts it in the top 3% of works published in 2017 by citations. It is open access: the full text is free to read at Europe PMC (PubMed Central).

Citations
132
Most cited in
2018 (23)
Field-weighted impact
1.24
References
91
Authors
7

Abstract

The blood-brain barrier is a dynamic and highly organized structure that strictly regulates the molecules allowed to cross the brain vasculature into the central nervous system. The blood-brain barrier pathology has been associated with a number of central nervous system diseases, including vascular malformations, stroke/vascular dementia, Alzheimer's disease, multiple sclerosis, and various neurological tumors including glioblastoma multiforme. There is a compelling need for representative models of this critical interface. Current research relies heavily on animal models (mostly mice) or on two-dimensional (2D) in vitro models, neither of which fully capture the complexities of the human blood-brain barrier. Physiological differences between humans and mice make translation to the clinic problematic, while monolayer cultures cannot capture the inherently three-dimensional (3D) nature of the blood-brain barrier, which includes close association of the abluminal side of the endothelium with astrocyte foot-processes and pericytes. Here we discuss the central nervous system diseases associated with blood-brain barrier pathology, recent advances in the development of novel 3D blood-brain barrier -on-a-chip systems that better mimic the physiological complexity and structure of human blood-brain barrier, and provide an outlook on how these blood-brain barrier-on-a-chip systems can be used for central nervous system disease modeling. Impact statement The field of microphysiological systems is rapidly evolving as new technologies are introduced and our understanding of organ physiology develops. In this review, we focus on Blood-Brain Barrier (BBB) models, with a particular emphasis on how they relate to neurological disorders such as Alzheimer's disease, multiple sclerosis, stroke, cancer, and vascular malformations. We emphasize the importance of capturing the three-dimensional nature of the brain and the unique architecture of the BBB - something that until recently had not been well modeled by in vitro systems. Our hope is that this review will provide a launch pad for new ideas and methodologies that can provide us with truly physiological BBB models capable of yielding new insights into the function of this critical interface.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Phan, D. T. T., Bender, R. H. F., Andrejecsk, J. W., Sobrino, A., Hachey, S. J., George, S. C., & Hughes, C. C. (2017). Blood–brain barrier-on-a-chip: Microphysiological systems that capture the complexity of the blood–central nervous system interface. Experimental Biology and Medicine, 242(17), 1669–1678. https://doi.org/10.1177/1535370217694100

MLA 9

Phan, Duc T. T., et al. “Blood–brain barrier-on-a-chip: Microphysiological systems that capture the complexity of the blood–central nervous system interface.” Experimental Biology and Medicine, vol. 242, no. 17, 2017, pp. 1669–1678. https://doi.org/10.1177/1535370217694100.

Chicago

Phan, Duc T. T., R. Hugh F. Bender, Jillian W. Andrejecsk, Agua Sobrino, Stephanie J. Hachey, Steven C. George, and Christopher C.W. Hughes. 2017. “Blood–brain barrier-on-a-chip: Microphysiological systems that capture the complexity of the blood–central nervous system interface.” Experimental Biology and Medicine 242 (17): 1669–1678. https://doi.org/10.1177/1535370217694100.

Harvard

Phan, D. T. T. et al. (2017) ‘Blood–brain barrier-on-a-chip: Microphysiological systems that capture the complexity of the blood–central nervous system interface’, Experimental Biology and Medicine, 242(17), pp. 1669–1678. doi:10.1177/1535370217694100.

IEEE

D. T. T. Phan et al., “Blood–brain barrier-on-a-chip: Microphysiological systems that capture the complexity of the blood–central nervous system interface,” Experimental Biology and Medicine, vol. 242, no. 17, pp. 1669–1678, 2017, doi: 10.1177/1535370217694100.

BibTeX

@article{phan2017blood,
  title     = {{Blood–brain barrier-on-a-chip: Microphysiological systems that capture the complexity of the blood–central nervous system interface}},
  author    = {Phan, Duc T. T. and Bender, R. Hugh F. and Andrejecsk, Jillian W. and Sobrino, Agua and Hachey, Stephanie J. and George, Steven C. and Hughes, Christopher C.W.},
  journal   = {Experimental Biology and Medicine},
  year      = {2017},
  volume    = {242},
  number    = {17},
  pages     = {1669--1678},
  doi       = {10.1177/1535370217694100},
  url       = {https://doi.org/10.1177/1535370217694100}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201744
20182323
20191616
20201313
20211515
20221616
20231414
20241717
202577
202677

Its field-weighted citation impact is 1.24: it has been cited 1.24 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies

  • blood-brain barrier
  • microphysiological systems
  • 3D in vitro model
  • Alzheimer's disease
  • multiple sclerosis
  • stroke
  • glioblastoma
  • vascular malformations

Work with this paper

Most-cited papers in Neuroscience

All highly cited Neuroscience papers

Questions about this paper

How do I cite this paper in APA style?

Phan, D. T. T., Bender, R. H. F., Andrejecsk, J. W., Sobrino, A., Hachey, S. J., George, S. C., & Hughes, C. C. (2017). Blood–brain barrier-on-a-chip: Microphysiological systems that capture the complexity of the blood–central nervous system interface. Experimental Biology and Medicine, 242(17), 1669–1678. https://doi.org/10.1177/1535370217694100

How many times has this paper been cited?

132 times, according to OpenAlex on 21 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Europe PMC (PubMed Central): sign in and open the full text from this page.

Who wrote this paper?

Duc T. T. Phan, R. Hugh F. Bender, Jillian W. Andrejecsk, Agua Sobrino, Stephanie J. Hachey, Steven C. George, Christopher C.W. Hughes.

What is the DOI of this paper?

10.1177/1535370217694100, permanently at https://doi.org/10.1177/1535370217694100. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 21 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.