Journal article · 2022

Bimorph electrothermal micro-gripper with large deformation, precise and rapid response, and low operating voltage

Xusheng Hui, Jianjun Luo, Xinliang Wang, Rong Wang, Hao Sun

Applied Physics Letters, 121(2), 023502 · Published 11 July 2022 · DOI 10.1063/5.0100920

View at the publisherCite this paper

In brief

“Bimorph electrothermal micro-gripper with large deformation, precise and rapid response, and low operating voltage” is a 2022 journal article by Xusheng Hui and 4 co-authors, published in Applied Physics Letters. OpenAlex counts 13 citations as of 22 November 2026, which puts it in the top 8% of works published in 2022 by citations. The publisher's version is not open access, and OpenAlex records no free legal copy.

Citations
13
Most cited in
2024 (4)
Field-weighted impact
0.64
References
39
Authors
5

Abstract

Micro-grippers are highly desired in engineering, robotics, and biomedicine. However, on the basis of satisfying the requirements of miniaturization, precise manipulation, and low power consumption, the existing micro-grippers are difficult to achieve rapid response simultaneously. In this paper, we present a bimorph electrothermal micro-gripper that composed of several metal ultrathin films with high surface-to-volume ratios… Read the full abstract at the publisher.

Excerpt. This paper is not open access.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Hui, X., Luo, J., Wang, X., Wang, R., & Sun, H. (2022). Bimorph electrothermal micro-gripper with large deformation, precise and rapid response, and low operating voltage. Applied Physics Letters, 121(2), 023502. https://doi.org/10.1063/5.0100920

MLA 9

Hui, Xusheng, et al. “Bimorph electrothermal micro-gripper with large deformation, precise and rapid response, and low operating voltage.” Applied Physics Letters, vol. 121, no. 2, 2022, p. 023502. https://doi.org/10.1063/5.0100920.

Chicago

Hui, Xusheng, Jianjun Luo, Xinliang Wang, Rong Wang, and Hao Sun. 2022. “Bimorph electrothermal micro-gripper with large deformation, precise and rapid response, and low operating voltage.” Applied Physics Letters 121 (2): 023502. https://doi.org/10.1063/5.0100920.

Harvard

Hui, X. et al. (2022) ‘Bimorph electrothermal micro-gripper with large deformation, precise and rapid response, and low operating voltage’, Applied Physics Letters, 121(2), p. 023502. doi:10.1063/5.0100920.

IEEE

X. Hui, J. Luo, X. Wang, R. Wang, and H. Sun, “Bimorph electrothermal micro-gripper with large deformation, precise and rapid response, and low operating voltage,” Applied Physics Letters, vol. 121, no. 2, p. 023502, 2022, doi: 10.1063/5.0100920.

BibTeX

@article{hui2022bimorph,
  title     = {{Bimorph electrothermal micro-gripper with large deformation, precise and rapid response, and low operating voltage}},
  author    = {Hui, Xusheng and Luo, Jianjun and Wang, Xinliang and Wang, Rong and Sun, Hao},
  journal   = {Applied Physics Letters},
  year      = {2022},
  volume    = {121},
  number    = {2},
  pages     = {023502},
  doi       = {10.1063/5.0100920},
  url       = {https://doi.org/10.1063/5.0100920}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
202322
202444
202544
202633

Its field-weighted citation impact is 0.64: it has been cited 0.64 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies

  • microgripper
  • bimorph actuators
  • electrothermal actuation
  • ultrathin metal films
  • rapid response
  • low-voltage operation
  • embedded circuits
  • current distribution

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Hui, X., Luo, J., Wang, X., Wang, R., & Sun, H. (2022). Bimorph electrothermal micro-gripper with large deformation, precise and rapid response, and low operating voltage. Applied Physics Letters, 121(2), 023502. https://doi.org/10.1063/5.0100920

How many times has this paper been cited?

13 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.

Who wrote this paper?

Xusheng Hui, Jianjun Luo, Xinliang Wang, Rong Wang, Hao Sun.

What is the DOI of this paper?

10.1063/5.0100920, permanently at https://doi.org/10.1063/5.0100920. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.