Review article · 2010 · Open access
Automatic de-identification of textual documents in the electronic health record: a review of recent research
BMC Medical Research Methodology, 10(1), 70 · Published 2 August 2010 · DOI 10.1186/1471-2288-10-70
In brief
“Automatic de-identification of textual documents in the electronic health record: a review of recent research” is a 2010 review article by Stéphane M. Meystre and 4 co-authors, published in BMC Medical Research Methodology. OpenAlex counts 425 citations as of 19 November 2026, which puts it in the top 1% of works published in 2010 by citations. It is open access under a CC BY licence: the full text is free to read at BMC Medical Research Methodology.
- Citations
- 425
- Most cited in
- 2025 (40)
- Field-weighted impact
- 3.45
- References
- 27
- Authors
- 5
Abstract
BACKGROUND: In the United States, the Health Insurance Portability and Accountability Act (HIPAA) protects the confidentiality of patient data and requires the informed consent of the patient and approval of the Internal Review Board to use data for research purposes, but these requirements can be waived if data is de-identified. For clinical data to be considered de-identified, the HIPAA "Safe Harbor" technique requires 18 data elements (called PHI: Protected Health Information) to be removed. The de-identification of narrative text documents is often realized manually, and requires significant resources. Well aware of these issues, several authors have investigated automated de-identification of narrative text documents from the electronic health record, and a review of recent research in this domain is presented here. METHODS: This review focuses on recently published research (after 1995), and includes relevant publications from bibliographic queries in PubMed, conference proceedings, the ACM Digital Library, and interesting publications referenced in already included papers. RESULTS: The literature search returned more than 200 publications. The majority focused only on structured data de-identification instead of narrative text, on image de-identification, or described manual de-identification, and were therefore excluded. Finally, 18 publications describing automated text de-identification were selected for detailed analysis of the architecture and methods used, the types of PHI detected and removed, the external resources used, and the types of clinical documents targeted. All text de-identification systems aimed to identify and remove person names, and many included other types of PHI. Most systems used only one or two specific clinical document types, and were mostly based on two different groups of methodologies: pattern matching and machine learning. Many systems combined both approaches for different types of PHI, but the majority relied only on pattern matching, rules, and dictionaries. CONCLUSIONS: In general, methods based on dictionaries performed better with PHI that is rarely mentioned in clinical text, but are more difficult to generalize. Methods based on machine learning tend to perform better, especially with PHI that is not mentioned in the dictionaries used. Finally, the issues of anonymization, sufficient performance, and "over-scrubbing" are discussed in this publication.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Meystre, S. M., Friedlin, J., South, B. R., Shen, S., & Samore, M. H. (2010). Automatic de-identification of textual documents in the electronic health record: a review of recent research. BMC Medical Research Methodology, 10(1), 70. https://doi.org/10.1186/1471-2288-10-70
MLA 9
Meystre, Stéphane M., et al. “Automatic de-identification of textual documents in the electronic health record: a review of recent research.” BMC Medical Research Methodology, vol. 10, no. 1, 2010, p. 70. https://doi.org/10.1186/1471-2288-10-70.
Chicago
Meystre, Stéphane M., Jeff Friedlin, Brett R. South, Shuying Shen, and Matthew H. Samore. 2010. “Automatic de-identification of textual documents in the electronic health record: a review of recent research.” BMC Medical Research Methodology 10 (1): 70. https://doi.org/10.1186/1471-2288-10-70.
Harvard
Meystre, S. M. et al. (2010) ‘Automatic de-identification of textual documents in the electronic health record: a review of recent research’, BMC Medical Research Methodology, 10(1), p. 70. doi:10.1186/1471-2288-10-70.
IEEE
S. M. Meystre, J. Friedlin, B. R. South, S. Shen, and M. H. Samore, “Automatic de-identification of textual documents in the electronic health record: a review of recent research,” BMC Medical Research Methodology, vol. 10, no. 1, p. 70, 2010, doi: 10.1186/1471-2288-10-70.
BibTeX
@article{meystre2010automatic,
title = {{Automatic de-identification of textual documents in the electronic health record: a review of recent research}},
author = {Meystre, Stéphane M. and Friedlin, Jeff and South, Brett R. and Shen, Shuying and Samore, Matthew H.},
journal = {BMC Medical Research Methodology},
year = {2010},
volume = {10},
number = {1},
pages = {70},
doi = {10.1186/1471-2288-10-70},
url = {https://doi.org/10.1186/1471-2288-10-70}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2017 | 20 | |
| 2018 | 18 | |
| 2019 | 35 | |
| 2020 | 22 | |
| 2021 | 34 | |
| 2022 | 25 | |
| 2023 | 28 | |
| 2024 | 31 | |
| 2025 | 40 | |
| 2026 | 33 |
Its field-weighted citation impact is 3.45: it has been cited 3.45 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Computer Science › Artificial Intelligence › Privacy-Preserving Technologies in Data
- electronic health records
- protected health information
- research data privacy
Work with this paper
Most-cited papers in Computer Science
- ImageNet classification with deep convolutional neural networksAlex Krizhevsky, Ilya Sutskever, Geoffrey E. Hinton · Communications of the ACM · 2017 · 114,726 citations
- Long Short-Term MemorySepp Hochreiter, Jürgen Schmidhuber · Neural Computation · 1997 · 109,097 citations
- A Mathematical Theory of CommunicationClaude E. Shannon · Bell System Technical Journal · 1948 · 91,736 citations
- Deep learningYann LeCun, Yoshua Bengio, Geoffrey E. Hinton · Nature · 2015 · 90,226 citations
- Faster R-CNN: Towards Real-Time Object Detection with Region Proposal NetworksShaoqing Ren, Kaiming He, Ross Girshick and 1 more · IEEE Transactions on Pattern Analysis and Machine Intelligence · 2016 · 74,143 citations
Questions about this paper
How do I cite this paper in APA style?
Meystre, S. M., Friedlin, J., South, B. R., Shen, S., & Samore, M. H. (2010). Automatic de-identification of textual documents in the electronic health record: a review of recent research. BMC Medical Research Methodology, 10(1), 70. https://doi.org/10.1186/1471-2288-10-70
How many times has this paper been cited?
425 times, according to OpenAlex on 19 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at BMC Medical Research Methodology: sign in and open the PDF from this page.
Who wrote this paper?
Stéphane M. Meystre, Jeff Friedlin, Brett R. South, Shuying Shen, Matthew H. Samore.
What is the DOI of this paper?
10.1186/1471-2288-10-70, permanently at https://doi.org/10.1186/1471-2288-10-70. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 19 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.