Journal article · 2023 · Open access

Atomic Resolution SE Imaging in a 30-200 keV Aberration-corrected UHV STEM

Michael T. Hotz, Joel Martis, Tomáš Radlička, N J Bacon, Niklas Dellby, T.C. Lovejoy, Steven C. Quillin, Harold Y. Hwang, Prastuti Singh, Ondrej L. Krivanek

Microscopy and Microanalysis, 29(Supplement_1), 2064–2065 · Published 22 July 2023 · DOI 10.1093/micmic/ozad067.1068

Open PDFView at the publisherCite this paper

In brief

“Atomic Resolution SE Imaging in a 30-200 keV Aberration-corrected UHV STEM” is a 2023 journal article by Michael T. Hotz and 9 co-authors, published in Microscopy and Microanalysis. OpenAlex counts 7 citations as of 19 November 2026, which puts it in the top 9% of works published in 2023 by citations. It is open access: the full text is free to read at Microscopy and Microanalysis.

Citations
7
Most cited in
2024 (3)
Field-weighted impact
0.58
References
5
Authors
10

Abstract

Images formed using secondary electrons (SE) in a scanning electron microscope (SEM) reveal surface features and can provide life-like images of 3D structures. The spatial resolution is a few nm at beam energies Eo of 1-30 keV, but it can be as good as 4 Å in 30 keV SEMs designed for high resolution [1]. However, this is still not enough to resolve atomic-scale surface structures, or to detect single atoms. SE images obtained in an Aberration-Corrected Scanning Transmission Electron Microscope (AC-STEM) able to form electron probes of 0.8 Å Ø at 200 keV showed that a significant part of the SE signal is sufficiently localized for resolution as good as 1.4 Å, and gave atomically resolved images of surfaces and of single heavy atoms [2-4]. But the imaging was not completely optimized: 200 keV primary energy results in smaller scattering cross-sections than Eo = 30 keV (typical SEM operating energy), increased knock-on radiation damage, and a slight increase in the SE signal delocalization [5]. Nion HERMES is a monochromated AC-STEM able to form 1 Å electron probes at Eo = 30 keV, using monochromation to overcome resolution loss due to chromatic aberration [6]. An advantage of HERMES for surface-sensitive SE imaging is that its sample chamber typically operates either in or close to ultra-high vacuum conditions (UHV, defined as <7.5×10−10 torr), and clean samples introduced into it stay clean indefinitely. We have therefore set out to investigate SE imaging with this microscope. Our SE detector was designed with the following goals: 1) minimize the deflection and instabilities the detector injects into the primary beam, which traverses it, 2) minimize extra aberrations imparted to the beam, 3) maximize the detector efficiency, and 4) avoid using single O-rings and make the detector bakeable, to preserve UHV environment at the sample. The detector uses the Everhart-Thornley detection principle [7] and can be situated either before or after the sample, or both. The results shown here use the before-the-sample configuration. Secondary electrons travel backwards from the sample's entrance surface through the objective lens, and are directed by an electrostatic deflector towards a scintillator biased up to +10 kV. The resultant photons are channeled into a photomultiplier tube. Applying a small voltage to the sample in a side-entry holder optimizes the efficiency of the SE signal detection, and it can also allow the range of detected SE energies to be varied. Initial tests of the SE detector showed that Au nanoparticles on the back side of a ∼20 nm thick amorphous carbon foil, which…

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Hotz, M. T., Martis, J., Radlička, T., Bacon, N. J., Dellby, N., Lovejoy, T., Quillin, S. C., Hwang, H. Y., Singh, P., & Krivanek, O. L. (2023). Atomic Resolution SE Imaging in a 30-200 keV Aberration-corrected UHV STEM. Microscopy and Microanalysis, 29(Supplement_1), 2064–2065. https://doi.org/10.1093/micmic/ozad067.1068

MLA 9

Hotz, Michael T., et al. “Atomic Resolution SE Imaging in a 30-200 keV Aberration-corrected UHV STEM.” Microscopy and Microanalysis, vol. 29, no. Supplement_1, 2023, pp. 2064–2065. https://doi.org/10.1093/micmic/ozad067.1068.

Chicago

Hotz, Michael T., Joel Martis, Tomáš Radlička, N J Bacon, Niklas Dellby, T.C. Lovejoy, Steven C. Quillin, Harold Y. Hwang, Prastuti Singh, and Ondrej L. Krivanek. 2023. “Atomic Resolution SE Imaging in a 30-200 keV Aberration-corrected UHV STEM.” Microscopy and Microanalysis 29 (Supplement_1): 2064–2065. https://doi.org/10.1093/micmic/ozad067.1068.

Harvard

Hotz, M. T. et al. (2023) ‘Atomic Resolution SE Imaging in a 30-200 keV Aberration-corrected UHV STEM’, Microscopy and Microanalysis, 29(Supplement_1), pp. 2064–2065. doi:10.1093/micmic/ozad067.1068.

IEEE

M. T. Hotz et al., “Atomic Resolution SE Imaging in a 30-200 keV Aberration-corrected UHV STEM,” Microscopy and Microanalysis, vol. 29, no. Supplement_1, pp. 2064–2065, 2023, doi: 10.1093/micmic/ozad067.1068.

BibTeX

@article{hotz2023atomic,
  title     = {{Atomic Resolution SE Imaging in a 30-200 keV Aberration-corrected UHV STEM}},
  author    = {Hotz, Michael T. and Martis, Joel and Radlička, Tomáš and Bacon, N J and Dellby, Niklas and Lovejoy, T.C. and Quillin, Steven C. and Hwang, Harold Y. and Singh, Prastuti and Krivanek, Ondrej L.},
  journal   = {Microscopy and Microanalysis},
  year      = {2023},
  volume    = {29},
  number    = {Supplement_1},
  pages     = {2064--2065},
  doi       = {10.1093/micmic/ozad067.1068},
  url       = {https://doi.org/10.1093/micmic/ozad067.1068}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
202433
202533
202611

Its field-weighted citation impact is 0.58: it has been cited 0.58 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Materials Science › Surfaces, Coatings and Films › Electron and X-Ray Spectroscopy Techniques

  • aberration-corrected scanning transmission electron microscopy
  • ultrahigh vacuum
  • electrostatic deflection
  • scintillators
  • photomultiplier tubes
  • single-atom detection
  • surface structure imaging

Work with this paper

Most-cited papers in Materials Science

All highly cited Materials Science papers

Questions about this paper

How do I cite this paper in APA style?

Hotz, M. T., Martis, J., Radlička, T., Bacon, N. J., Dellby, N., Lovejoy, T., Quillin, S. C., Hwang, H. Y., Singh, P., & Krivanek, O. L. (2023). Atomic Resolution SE Imaging in a 30-200 keV Aberration-corrected UHV STEM. Microscopy and Microanalysis, 29(Supplement_1), 2064–2065. https://doi.org/10.1093/micmic/ozad067.1068

How many times has this paper been cited?

7 times, according to OpenAlex on 19 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Microscopy and Microanalysis: sign in and open the PDF from this page.

Who wrote this paper?

Michael T. Hotz, Joel Martis, Tomáš Radlička, N J Bacon, Niklas Dellby, T.C. Lovejoy, Steven C. Quillin, Harold Y. Hwang, Prastuti Singh, Ondrej L. Krivanek.

What is the DOI of this paper?

10.1093/micmic/ozad067.1068, permanently at https://doi.org/10.1093/micmic/ozad067.1068. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 19 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.