“Analytical Validation of Aptamer-Based Serum Vancomycin Monitoring Relative to Automated Immunoassays” is a 2023 journal article by Yu Liu and 7 co-authors, published in ACS Sensors. OpenAlex counts 28 citations as of 19 November 2026, which puts it in the top 2% of works published in 2023 by citations. It is open access under a CC BY-NC-ND licence: the full text is free to read at ACS Sensors.

Citations
28
Most cited in
2026 (12)
Field-weighted impact
2.01
References
19
Authors
8

Abstract

The practice of monitoring therapeutic drug concentrations in patient biofluids can significantly improve clinical outcomes while simultaneously minimizing adverse side effects. A model example of this practice is vancomycin dosing in intensive care units. If dosed correctly, vancomycin can effectively treat methicillin-resistant streptococcus aureus (MRSA) infections. However, it can also induce nephrotoxicity or fail to kill the bacteria if dosed too high or too low, respectively. Although undeniably important to achieve effectiveness, therapeutic drug monitoring remains inconvenient in practice due primarily to the lengthy process of sample collection, transport to a centralized facility, and analysis using costly instrumentation. Adding to this workflow is the possibility of backlogs at centralized clinical laboratories, which is not uncommon and may result in additional delays between biofluid sampling and concentration measurement, which can negatively affect clinical outcomes. Here, we explore the possibility of using point-of-care electrochemical aptamer-based (E-AB) sensors to minimize the time delay between biofluid sampling and drug measurement. Specifically, we conducted a clinical agreement study comparing the measurement outcomes of E-AB sensors to the benchmark automated competitive immunoassays for vancomycin monitoring in serum. Our results demonstrate that E-ABs are selective for free vancomycin─the active form of the drug, over total vancomycin. In contrast, competitive immunoassays measure total vancomycin, including both protein-bound and free drug. Accounting for these differences in a pilot study consisting of 85 clinical samples, we demonstrate that the E-AB vancomycin measurement achieved a 95% positive correlation rate with the benchmark immunoassays. Therefore, we conclude that E-AB sensors could provide clinically useful stratification of patient samples at trough sampling to guide effective vancomycin dose recommendations.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Liu, Y., Mack, J. O., Shojaee, M., Shaver, A., George, A., Clarke, W. A., Patel, N., & Arroyo‐Currás, N. (2023). Analytical Validation of Aptamer-Based Serum Vancomycin Monitoring Relative to Automated Immunoassays. ACS Sensors, 9(1), 228–235. https://doi.org/10.1021/acssensors.3c01868

MLA 9

Liu, Yu, et al. “Analytical Validation of Aptamer-Based Serum Vancomycin Monitoring Relative to Automated Immunoassays.” ACS Sensors, vol. 9, no. 1, 2023, pp. 228–235. https://doi.org/10.1021/acssensors.3c01868.

Chicago

Liu, Yu, John O. Mack, Maryam Shojaee, Alexander Shaver, Ankitha George, William A. Clarke, Neel Patel, and Netzahualcóyotl Arroyo‐Currás. 2023. “Analytical Validation of Aptamer-Based Serum Vancomycin Monitoring Relative to Automated Immunoassays.” ACS Sensors 9 (1): 228–235. https://doi.org/10.1021/acssensors.3c01868.

Harvard

Liu, Y. et al. (2023) ‘Analytical Validation of Aptamer-Based Serum Vancomycin Monitoring Relative to Automated Immunoassays’, ACS Sensors, 9(1), pp. 228–235. doi:10.1021/acssensors.3c01868.

IEEE

Y. Liu et al., “Analytical Validation of Aptamer-Based Serum Vancomycin Monitoring Relative to Automated Immunoassays,” ACS Sensors, vol. 9, no. 1, pp. 228–235, 2023, doi: 10.1021/acssensors.3c01868.

BibTeX

@article{liu2023analytical,
  title     = {{Analytical Validation of Aptamer-Based Serum Vancomycin Monitoring Relative to Automated Immunoassays}},
  author    = {Liu, Yu and Mack, John O. and Shojaee, Maryam and Shaver, Alexander and George, Ankitha and Clarke, William A. and Patel, Neel and Arroyo‐Currás, Netzahualcóyotl},
  journal   = {ACS Sensors},
  year      = {2023},
  volume    = {9},
  number    = {1},
  pages     = {228--235},
  doi       = {10.1021/acssensors.3c01868},
  url       = {https://doi.org/10.1021/acssensors.3c01868}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
202477
202599
20261212

Its field-weighted citation impact is 2.01: it has been cited 2.01 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques

  • vancomycin
  • therapeutic drug monitoring
  • point-of-care testing
  • serum drug concentration
  • competitive immunoassay
  • methicillin-resistant Staphylococcus aureus
  • nephrotoxicity
  • dosage

Work with this paper

Most-cited papers in Biochemistry, Genetics and Molecular Biology

All highly cited Biochemistry, Genetics and Molecular Biology papers

Questions about this paper

How do I cite this paper in APA style?

Liu, Y., Mack, J. O., Shojaee, M., Shaver, A., George, A., Clarke, W. A., Patel, N., & Arroyo‐Currás, N. (2023). Analytical Validation of Aptamer-Based Serum Vancomycin Monitoring Relative to Automated Immunoassays. ACS Sensors, 9(1), 228–235. https://doi.org/10.1021/acssensors.3c01868

How many times has this paper been cited?

28 times, according to OpenAlex on 19 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at ACS Sensors: sign in and open the PDF from this page.

Who wrote this paper?

Yu Liu, John O. Mack, Maryam Shojaee, Alexander Shaver, Ankitha George, William A. Clarke, Neel Patel, Netzahualcóyotl Arroyo‐Currás.

What is the DOI of this paper?

10.1021/acssensors.3c01868, permanently at https://doi.org/10.1021/acssensors.3c01868. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 19 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.