Paper · 2007 · Open access

Analysis of beam-to-column bolted flush end plate connections

Foces Mediavilla, Antonio, Garrido Hernández, Antonio, Moreno

UPCommons institutional repository (Universitat Politècnica de Catalunya) · Published 1 January 2007

Open full textCite this paper

In brief

“Analysis of beam-to-column bolted flush end plate connections” is a 2007 paper by Foces Mediavilla, Antonio and 2 co-authors, published in UPCommons institutional repository (Universitat Politècnica de Catalunya). OpenAlex counts 0 citations as of 22 November 2026. It is open access: the full text is free to read at UPCommons institutional repository (Universitat Politècnica de Catalunya).

Citations
0
References
16
Authors
3

Abstract

Hoy en día está ampliamente reconocido que las uniones y los elementos de una estructura met´alica presentan un comportamiento semirrígido y no lineal, teniendo los estudios actuales como objetivo incorporar tales conceptos en los métodos de diseño y análisis. El presente trabajo se centra en el estudio de las uniones atornilladas viga–pilar realizadas con chapa frontal a tope, tipo de unión ampliamente utilizada por ser de fácil fabricación y montaje, con el objetivo de predecir su comportamiento rotacional (curva momento–rotación) para que pueda ser incorporado en el análisis de la estructura. Para la determinación del comportamiento rotacional del mencionado tipo de unión se ha realizado un modelo tridimensional de elementos finitos para ser analizado mediante el paquete de software COSMOS/MR. Dicho modelo contempla la compleja interacción entre los diversos elementos que la componen. Así se han modelado la viga, la chapa frontal, los tornillos (pernos y tuercas) y el lado del pilar. Además, como ley de comportamiento del acero, tanto para los elementos a unir como para los tornillos, se utiliza el diagrama bilineal correspondiente a un comportamiento elástico–perfectamente plástico. Para la validación del modelo propuesto se han comparado los resultados que arroja con los deducidos teóricamente siguiendo las recomendaciones del Eurocódigo 3 (unión equivalente en T y Teoría de las Líneas de Rotura) y con los obtenidos experimentalmente.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Antonio, F. M., Antonio, G. H., & Moreno. (2007). Analysis of beam-to-column bolted flush end plate connections. UPCommons institutional repository (Universitat Politècnica de Catalunya). https://hdl.handle.net/2099/10343

MLA 9

Antonio, Foces Mediavilla,, et al. “Analysis of beam-to-column bolted flush end plate connections.” UPCommons institutional repository (Universitat Politècnica de Catalunya), 2007. https://hdl.handle.net/2099/10343.

Chicago

Antonio, Foces Mediavilla,, Garrido Hernández, Antonio, and Moreno. 2007. “Analysis of beam-to-column bolted flush end plate connections.” UPCommons institutional repository (Universitat Politècnica de Catalunya). https://hdl.handle.net/2099/10343.

Harvard

Antonio, F. M., Antonio, G. H. and Moreno (2007) ‘Analysis of beam-to-column bolted flush end plate connections’, UPCommons institutional repository (Universitat Politècnica de Catalunya). Available at: https://hdl.handle.net/2099/10343.

IEEE

F. M. Antonio, G. H. Antonio, and Moreno, “Analysis of beam-to-column bolted flush end plate connections,” UPCommons institutional repository (Universitat Politècnica de Catalunya), 2007.

BibTeX

@article{antonio2007analysis,
  title     = {{Analysis of beam-to-column bolted flush end plate connections}},
  author    = {Antonio, Foces Mediavilla, and Antonio, Garrido Hernández, and Moreno},
  journal   = {UPCommons institutional repository (Universitat Politècnica de Catalunya)},
  year      = {2007},
  url       = {https://hdl.handle.net/2099/10343}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Physical Sciences › Engineering › Civil and Structural Engineering › Structural Load-Bearing Analysis

  • beam-column joints
  • moment-rotation curves
  • rotational behavior
  • steel connections
  • finite element analysis
  • Eurocode 3

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Antonio, F. M., Antonio, G. H., & Moreno. (2007). Analysis of beam-to-column bolted flush end plate connections. UPCommons institutional repository (Universitat Politècnica de Catalunya). https://hdl.handle.net/2099/10343

How many times has this paper been cited?

0 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at UPCommons institutional repository (Universitat Politècnica de Catalunya): sign in and open the full text from this page.

Who wrote this paper?

Foces Mediavilla, Antonio, Garrido Hernández, Antonio, Moreno.

Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.