“análise exergética da fábrica de aromáticos da refinaria de matosinhos” is a 2015 dissertation by Ana Alexandra dos Santos Neves Vilarinho, published in Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT). OpenAlex counts 0 citations as of 22 November 2026. It is open access: the full text is free to read at Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT).
- Citations
- 0
- References
- 58
- Authors
- 1
Abstract
Análise Exergética da Fábrica de Aromáticos da Refinaria de Matosinhos xi Resumo Muitos processos da indústria química consomem demasiada energia e frequentemente operam de forma ineficiente.Tal implica elevados custos operacionais, os quais podem ser reduzidos através de melhorias no uso de energia no processo.Neste trabalho são realizados balanços energéticos e exergéticos às unidades de prédestilação (Un-0100), Arosolvan (Un-0200), Parex (Un-0300), Isomar (Un-0400) e de produção de solventes (Un-0500) da Fábrica de Aromáticos da Refinaria de Matosinhos, com o objetivo de se determinar os seus rendimentos energéticos e exergéticos, desconhecidos até ao presente trabalho.Uma vez que os resultados obtidos se encontram abaixo do que era espectável, foi realizado um levantamento com vista à hierarquização das perdas energéticas e irreversibilidades ocorridas nas unidades.Na sua análise global, a FAR apresentou um rendimento energético de 0,8 % e um rendimento exergético de 65,9 %.Deve-se referir que nesta análise, não foram alvo de estudo alguns equipamentos, nomeadamente nas Unidades 0200 e 0500, por falta de dados que permitissem a sua análise.Estas situações estão contempladas nas perdas e irreversibilidades não contabilizadas, que na análise global da FAR, constituem 33,2 % e 28,2 %, respetivamente.Os equipamentos que apresentam maiores perdas energéticas na FAR, são os condensadores, representando 26,1 % das perdas energéticas, seguindo-se os aeroarrefecedores, com 15,6 % das perdas energéticas, pelo que se pode concluir que grande parte da energia perdida na FAR, é devida ao processo de arrefecimento.As irreversibilidades verificadas nestes grupos de equipamentos foram de 0,55 % e 0,29 %, respetivamente.Relativamente aos permutadores, as perdas energéticas não são muito significativas, face aos restantes grupos de equipamentos (3,1 % de perdas energéticas), bem como as irreversibilidades que representam 0,1 % das irreversibilidades totais da FAR.Por outro lado, as fornalhas representam 14,8 % das perdas energéticas, mas estes equipamentos destacam-se sobretudo pelas irreversibilidades verificadas, 84,2 % do total.Com base neste valor, depreende-se que são equipamentos com um elevado potencial de melhoria do desempenho energético e exergético, com natural impacto positivo no desempenho energético e exergético da FAR.Análise Exergética da Fábrica de Aromáticos da Refinaria de Matosinhos xii Entre outras medidas, são sugeridas duas soluções de forma a se poder atuar onde ocorrem as maiores perdas.Neste sentido, propõe-se um sistema de aproveitamento do calor perdido nos aeroarrefecedores e fornalha que consiste num ciclo de Rankine orgânico que aumentaria o rendimento energético e exergético da FAR em cerca de 7 % e 1 %, respetivamente e que produziria cerca de 1500 kW de energia elétrica.A outra solução consiste na adoção conjunta de um sistema de cogeração com o…
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Vilarinho, A. A. D. S. N. (2015). análise exergética da fábrica de aromáticos da refinaria de matosinhos. Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT). https://doi.org/10.34626/c0g8-1n64
MLA 9
Vilarinho, Ana Alexandra dos Santos Neves. “análise exergética da fábrica de aromáticos da refinaria de matosinhos.” Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT), 2015. https://doi.org/10.34626/c0g8-1n64.
Chicago
Vilarinho, Ana Alexandra dos Santos Neves. 2015. “análise exergética da fábrica de aromáticos da refinaria de matosinhos.” Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT). https://doi.org/10.34626/c0g8-1n64.
Harvard
Vilarinho, A. A. D. S. N. (2015) ‘análise exergética da fábrica de aromáticos da refinaria de matosinhos’, Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT). doi:10.34626/c0g8-1n64.
IEEE
A. A. D. S. N. Vilarinho, “análise exergética da fábrica de aromáticos da refinaria de matosinhos,” Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT), 2015, doi: 10.34626/c0g8-1n64.
BibTeX
@phdthesis{vilarinho2015lise,
title = {{análise exergética da fábrica de aromáticos da refinaria de matosinhos}},
author = {Vilarinho, Ana Alexandra dos Santos Neves},
year = {2015},
doi = {10.34626/c0g8-1n64},
url = {https://doi.org/10.34626/c0g8-1n64}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Physical Sciences › Engineering › Mechanical Engineering › Thermodynamic and Exergetic Analyses of Power and Cooling Systems
- exergy analysis
- energy balance
- exergy balance
- exergy destruction
- energy loss
- condenser
- air coolers
- heat exchangers
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
Vilarinho, A. A. D. S. N. (2015). análise exergética da fábrica de aromáticos da refinaria de matosinhos. Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT). https://doi.org/10.34626/c0g8-1n64
How many times has this paper been cited?
0 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT): sign in and open the PDF from this page.
Who wrote this paper?
Ana Alexandra dos Santos Neves Vilarinho.
What is the DOI of this paper?
10.34626/c0g8-1n64, permanently at https://doi.org/10.34626/c0g8-1n64. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.