Journal article · 2010 · Open access
Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod
American Journal of Analytical Chemistry, 01(02), 41–46 · Published 1 January 2010 · DOI 10.4236/ajac.2010.12006
In brief
“Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod” is a 2010 journal article by Nidhi Chauhan and 2 co-authors, published in American Journal of Analytical Chemistry. OpenAlex counts 26 citations as of 15 November 2026. It is open access under a CC BY licence: the full text is free to read at American Journal of Analytical Chemistry.
- Citations
- 26
- Most cited in
- 2016 (4)
- Field-weighted impact
- 0.43
- References
- 27
- Authors
- 3
Abstract
A cholesterol oxidase from Streptomycin sp. was immobilized onto pencil graphite rod and employed for amperometric determination of serum cholesterol. The method has the advantage over earlier amperometric methods that it requires low potential to generate electrons from H2O2, which does not allow ionization of serum substances. The optimum working conditions of amperometric determination were pH 6.8, 25?C and 30 s. The current measured was in proportion to cholesterol concentration ranging from 1.29×10-3 to 10.33×10-3 M. Minimum detection limit of the method was 0.09 ×10-3 M. Mean analytical recovery of added cholesterol (100 mg/dl and 200 mg/dl) in serum was 85.0% & 90.0% respectively. Within batch and between batch coefficients of variations were 1.59% & 4.15% respectively. A good correlation (r = 0.99) was obtained between serum cholesterol values by standard enzymic colorimetric method and the present method. No interference by metabolites was observed in the method. The enzyme electrode was reused 200 times over a period of 25 days, when stored at 4?C
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Chauhan, N., Narang, J., & Pundir, C. S. (2010). Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod. American Journal of Analytical Chemistry, 01(02), 41–46. https://doi.org/10.4236/ajac.2010.12006
MLA 9
Chauhan, Nidhi, et al. “Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod.” American Journal of Analytical Chemistry, vol. 01, no. 02, 2010, pp. 41–46. https://doi.org/10.4236/ajac.2010.12006.
Chicago
Chauhan, Nidhi, Jagriti Narang, and Chandra Shekhar Pundir. 2010. “Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod.” American Journal of Analytical Chemistry 01 (02): 41–46. https://doi.org/10.4236/ajac.2010.12006.
Harvard
Chauhan, N., Narang, J. and Pundir, C. S. (2010) ‘Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod’, American Journal of Analytical Chemistry, 01(02), pp. 41–46. doi:10.4236/ajac.2010.12006.
IEEE
N. Chauhan, J. Narang, and C. S. Pundir, “Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod,” American Journal of Analytical Chemistry, vol. 01, no. 02, pp. 41–46, 2010, doi: 10.4236/ajac.2010.12006.
BibTeX
@article{chauhan2010amperometric,
title = {{Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod}},
author = {Chauhan, Nidhi and Narang, Jagriti and Pundir, Chandra Shekhar},
journal = {American Journal of Analytical Chemistry},
year = {2010},
volume = {01},
number = {02},
pages = {41--46},
doi = {10.4236/ajac.2010.12006},
url = {https://doi.org/10.4236/ajac.2010.12006}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2016 | 4 | |
| 2017 | 1 | |
| 2018 | 2 | |
| 2019 | 1 | |
| 2020 | 2 | |
| 2021 | 1 | |
| 2023 | 2 | |
| 2024 | 3 | |
| 2025 | 1 | |
| 2026 | 2 |
Its field-weighted citation impact is 0.43: it has been cited 0.43 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- serum cholesterol
- amperometric detection
- cholesterol oxidase
- enzyme immobilization
- enzyme electrodes
- hydrogen peroxide
- electrochemical biosensor
- electrode reusability
Work with this paper
Most-cited papers in Chemistry
- CRC Handbook of Chemistry and PhysicsW.M. Haynes · CRC Press eBooks · 2014 · 58,210 citations
- Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets: procedure and some applications.Harry Towbin, Th. Staehelin, J Gordon · Proceedings of the National Academy of Sciences · 1979 · 53,242 citations
- Crystal structure refinement with SHELXLGeorge M. Sheldrick · Acta Crystallographica Section C Structural Chemistry · 2014 · 45,305 citations
- Comparison of simple potential functions for simulating liquid waterWilliam L. Jorgensen, Jayaraman Chandrasekhar, Jeffry D. Madura and 2 more · The Journal of Chemical Physics · 1983 · 41,735 citations
- Equation of State Calculations by Fast Computing MachinesN. Metropolis, Arianna W. Rosenbluth, M. N. Rosenbluth and 2 more · The Journal of Chemical Physics · 1953 · 38,111 citations
Questions about this paper
How do I cite this paper in APA style?
Chauhan, N., Narang, J., & Pundir, C. S. (2010). Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod. American Journal of Analytical Chemistry, 01(02), 41–46. https://doi.org/10.4236/ajac.2010.12006
How many times has this paper been cited?
26 times, according to OpenAlex on 15 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access: read the free full text at American Journal of Analytical Chemistry.
Who wrote this paper?
Nidhi Chauhan, Jagriti Narang, Chandra Shekhar Pundir.
What is the DOI of this paper?
10.4236/ajac.2010.12006. The permanent link is https://doi.org/10.4236/ajac.2010.12006.
Bibliographic data from OpenAlex (CC0), last checked 15 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.