Journal article · 2010 · Open access

Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod

Nidhi Chauhan, Jagriti Narang, Chandra Shekhar Pundir

American Journal of Analytical Chemistry, 01(02), 41–46 · Published 1 January 2010 · DOI 10.4236/ajac.2010.12006

Free PDFView at the publisherCite this paper

In brief

“Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod” is a 2010 journal article by Nidhi Chauhan and 2 co-authors, published in American Journal of Analytical Chemistry. OpenAlex counts 26 citations as of 15 November 2026. It is open access under a CC BY licence: the full text is free to read at American Journal of Analytical Chemistry.

Citations
26
Most cited in
2016 (4)
Field-weighted impact
0.43
References
27
Authors
3

Abstract

A cholesterol oxidase from Streptomycin sp. was immobilized onto pencil graphite rod and employed for amperometric determination of serum cholesterol. The method has the advantage over earlier amperometric methods that it requires low potential to generate electrons from H2O2, which does not allow ionization of serum substances. The optimum working conditions of amperometric determination were pH 6.8, 25?C and 30 s. The current measured was in proportion to cholesterol concentration ranging from 1.29×10-3 to 10.33×10-3 M. Minimum detection limit of the method was 0.09 ×10-3 M. Mean analytical recovery of added cholesterol (100 mg/dl and 200 mg/dl) in serum was 85.0% & 90.0% respectively. Within batch and between batch coefficients of variations were 1.59% & 4.15% respectively. A good correlation (r = 0.99) was obtained between serum cholesterol values by standard enzymic colorimetric method and the present method. No interference by metabolites was observed in the method. The enzyme electrode was reused 200 times over a period of 25 days, when stored at 4?C

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Chauhan, N., Narang, J., & Pundir, C. S. (2010). Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod. American Journal of Analytical Chemistry, 01(02), 41–46. https://doi.org/10.4236/ajac.2010.12006

MLA 9

Chauhan, Nidhi, et al. “Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod.” American Journal of Analytical Chemistry, vol. 01, no. 02, 2010, pp. 41–46. https://doi.org/10.4236/ajac.2010.12006.

Chicago

Chauhan, Nidhi, Jagriti Narang, and Chandra Shekhar Pundir. 2010. “Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod.” American Journal of Analytical Chemistry 01 (02): 41–46. https://doi.org/10.4236/ajac.2010.12006.

Harvard

Chauhan, N., Narang, J. and Pundir, C. S. (2010) ‘Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod’, American Journal of Analytical Chemistry, 01(02), pp. 41–46. doi:10.4236/ajac.2010.12006.

IEEE

N. Chauhan, J. Narang, and C. S. Pundir, “Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod,” American Journal of Analytical Chemistry, vol. 01, no. 02, pp. 41–46, 2010, doi: 10.4236/ajac.2010.12006.

BibTeX

@article{chauhan2010amperometric,
  title     = {{Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod}},
  author    = {Chauhan, Nidhi and Narang, Jagriti and Pundir, Chandra Shekhar},
  journal   = {American Journal of Analytical Chemistry},
  year      = {2010},
  volume    = {01},
  number    = {02},
  pages     = {41--46},
  doi       = {10.4236/ajac.2010.12006},
  url       = {https://doi.org/10.4236/ajac.2010.12006}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201644
201711
201822
201911
202022
202111
202322
202433
202511
202622

Its field-weighted citation impact is 0.43: it has been cited 0.43 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors

  • serum cholesterol
  • amperometric detection
  • cholesterol oxidase
  • enzyme immobilization
  • enzyme electrodes
  • hydrogen peroxide
  • electrochemical biosensor
  • electrode reusability

Work with this paper

Most-cited papers in Chemistry

All highly cited Chemistry papers

Questions about this paper

How do I cite this paper in APA style?

Chauhan, N., Narang, J., & Pundir, C. S. (2010). Amperometric Determination of Serum Cholesterol with Pencil Graphite Rod. American Journal of Analytical Chemistry, 01(02), 41–46. https://doi.org/10.4236/ajac.2010.12006

How many times has this paper been cited?

26 times, according to OpenAlex on 15 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access: read the free full text at American Journal of Analytical Chemistry.

Who wrote this paper?

Nidhi Chauhan, Jagriti Narang, Chandra Shekhar Pundir.

What is the DOI of this paper?

10.4236/ajac.2010.12006. The permanent link is https://doi.org/10.4236/ajac.2010.12006.

Bibliographic data from OpenAlex (CC0), last checked 15 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.