Journal article · 2009

Amorphous selenium and its alloys from early xeroradiography to high resolution X‐ray image detectors and ultrasensitive imaging tubes

Safa O Kasap, Joel B. Frey, George S. Belev, Olivier Tousignant, H. Mani, Luc Laperrière, Alla Reznik, J. A. Rowlands

physica status solidi (b), 246(8), 1794–1805 · Published 6 July 2009 · DOI 10.1002/pssb.200982007

View at the publisherCite this paper

In brief

“Amorphous selenium and its alloys from early xeroradiography to high resolution X‐ray image detectors and ultrasensitive imaging tubes” is a 2009 journal article by Safa O Kasap and 7 co-authors, published in physica status solidi (b). OpenAlex counts 200 citations as of 16 November 2026, which puts it in the top 3% of works published in 2009 by citations. The publisher's version is not open access, and OpenAlex records no free legal copy.

Citations
200
Most cited in
2024 (23)
Field-weighted impact
6.57
References
48
Authors
8

Abstract

We describe the progress in the science and technology of stabilized a‐Se from its early use in xerography and xeroradiography to its present use in commercial modern flat panel X‐ray imagers and ultrasensitive video tubes which utilize impact ionization of drifting holes. Both electrons and holes can drift in stabilized a‐Se, which is a distinct… Read the full abstract at the publisher.

Excerpt. This paper is not open access.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Kasap, S. O., Frey, J. B., Belev, G. S., Tousignant, O., Mani, H., Laperrière, L., Reznik, A., & Rowlands, J. A. (2009). Amorphous selenium and its alloys from early xeroradiography to high resolution X‐ray image detectors and ultrasensitive imaging tubes. physica status solidi (b), 246(8), 1794–1805. https://doi.org/10.1002/pssb.200982007

MLA 9

Kasap, Safa O, et al. “Amorphous selenium and its alloys from early xeroradiography to high resolution X‐ray image detectors and ultrasensitive imaging tubes.” physica status solidi (b), vol. 246, no. 8, 2009, pp. 1794–1805. https://doi.org/10.1002/pssb.200982007.

Chicago

Kasap, Safa O, Joel B. Frey, George S. Belev, Olivier Tousignant, H. Mani, Luc Laperrière, Alla Reznik, and J. A. Rowlands. 2009. “Amorphous selenium and its alloys from early xeroradiography to high resolution X‐ray image detectors and ultrasensitive imaging tubes.” physica status solidi (b) 246 (8): 1794–1805. https://doi.org/10.1002/pssb.200982007.

Harvard

Kasap, S. O. et al. (2009) ‘Amorphous selenium and its alloys from early xeroradiography to high resolution X‐ray image detectors and ultrasensitive imaging tubes’, physica status solidi (b), 246(8), pp. 1794–1805. doi:10.1002/pssb.200982007.

IEEE

S. O. Kasap et al., “Amorphous selenium and its alloys from early xeroradiography to high resolution X‐ray image detectors and ultrasensitive imaging tubes,” physica status solidi (b), vol. 246, no. 8, pp. 1794–1805, 2009, doi: 10.1002/pssb.200982007.

BibTeX

@article{kasap2009amorphous,
  title     = {{Amorphous selenium and its alloys from early xeroradiography to high resolution X‐ray image detectors and ultrasensitive imaging tubes}},
  author    = {Kasap, Safa O and Frey, Joel B. and Belev, George S. and Tousignant, Olivier and Mani, H. and Laperrière, Luc and Reznik, Alla and Rowlands, J. A.},
  journal   = {physica status solidi (b)},
  year      = {2009},
  volume    = {246},
  number    = {8},
  pages     = {1794--1805},
  doi       = {10.1002/pssb.200982007},
  url       = {https://doi.org/10.1002/pssb.200982007}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
20171111
201844
201988
20201414
20211212
20221414
20231818
20242323
20251919
20261515

Its field-weighted citation impact is 6.57: it has been cited 6.57 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Semiconductor Detectors and Materials

  • amorphous selenium
  • xeroradiography
  • xerography
  • impact ionization
  • photoconductive layer
  • dark current
  • multilayer device structure
  • detective quantum efficiency

Work with this paper

Most-cited papers in Engineering

All highly cited Engineering papers

Questions about this paper

How do I cite this paper in APA style?

Kasap, S. O., Frey, J. B., Belev, G. S., Tousignant, O., Mani, H., Laperrière, L., Reznik, A., & Rowlands, J. A. (2009). Amorphous selenium and its alloys from early xeroradiography to high resolution X‐ray image detectors and ultrasensitive imaging tubes. physica status solidi (b), 246(8), 1794–1805. https://doi.org/10.1002/pssb.200982007

How many times has this paper been cited?

200 times, according to OpenAlex on 16 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.

Who wrote this paper?

Safa O Kasap, Joel B. Frey, George S. Belev, Olivier Tousignant, H. Mani, Luc Laperrière, Alla Reznik, J. A. Rowlands.

What is the DOI of this paper?

10.1002/pssb.200982007. The permanent link is https://doi.org/10.1002/pssb.200982007.

Bibliographic data from OpenAlex (CC0), last checked 16 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.