Review article · 2011 · Open access
Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors
Sensors, 11(5), 5112–5157 · Published 9 May 2011 · DOI 10.3390/s110505112
In brief
“Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors” is a 2011 review article by Safa O Kasap and 11 co-authors, published in Sensors. OpenAlex counts 564 citations as of 24 November 2026, which puts it in the top 1% of works published in 2011 by citations. It is open access under a CC BY licence: the full text is free to read at Sensors.
- Citations
- 564
- Most cited in
- 2025 (58)
- Field-weighted impact
- 2.26
- References
- 164
- Authors
- 12
Abstract
In the last ten to fifteen years there has been much research in using amorphous and polycrystalline semiconductors as x-ray photoconductors in various x-ray image sensor applications, most notably in flat panel x-ray imagers (FPXIs). We first outline the essential requirements for an ideal large area photoconductor for use in a FPXI, and discuss how some of the current amorphous and polycrystalline semiconductors fulfill these requirements. At present, only stabilized amorphous selenium (doped and alloyed a-Se) has been commercialized, and FPXIs based on a-Se are particularly suitable for mammography, operating at the ideal limit of high detective quantum efficiency (DQE). Further, these FPXIs can also be used in real-time, and have already been used in such applications as tomosynthesis. We discuss some of the important attributes of amorphous and polycrystalline x-ray photoconductors such as their large area deposition ability, charge collection efficiency, x-ray sensitivity, DQE, modulation transfer function (MTF) and the importance of the dark current. We show the importance of charge trapping in limiting not only the sensitivity but also the resolution of these detectors. Limitations on the maximum acceptable dark current and the corresponding charge collection efficiency jointly impose a practical constraint that many photoconductors fail to satisfy. We discuss the case of a-Se in which the dark current was brought down by three orders of magnitude by the use of special blocking layers to satisfy the dark current constraint. There are also a number of polycrystalline photoconductors, HgI(2) and PbO being good examples, that show potential for commercialization in the same way that multilayer stabilized a-Se x-ray photoconductors were developed for commercial applications. We highlight the unique nature of avalanche multiplication in a-Se and how it has led to the development of the commercial HARP video-tube. An all solid state version of the HARP has been recently demonstrated with excellent avalanche gains; the latter is expected to lead to a number of novel imaging device applications that would be quantum noise limited. While passive pixel sensors use one TFT (thin film transistor) as a switch at the pixel, active pixel sensors (APSs) have two or more transistors and provide gain at the pixel level. The advantages of APS based x-ray imagers are also discussed with examples.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Kasap, S. O., Frey, J. B., Belev, G. S., Tousignant, O., Mani, H., Greenspan, J., Laperrière, L., Bubon, O., Reznik, A., DeCrescenzo, G., Karim, K. S., & Rowlands, J. A. (2011). Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors. Sensors, 11(5), 5112–5157. https://doi.org/10.3390/s110505112
MLA 9
Kasap, Safa O, et al. “Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors.” Sensors, vol. 11, no. 5, 2011, pp. 5112–5157. https://doi.org/10.3390/s110505112.
Chicago
Kasap, Safa O, Joel B. Frey, George S. Belev, Olivier Tousignant, H. Mani, J. Greenspan, Luc Laperrière, et al. 2011. “Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors.” Sensors 11 (5): 5112–5157. https://doi.org/10.3390/s110505112.
Harvard
Kasap, S. O. et al. (2011) ‘Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors’, Sensors, 11(5), pp. 5112–5157. doi:10.3390/s110505112.
IEEE
S. O. Kasap et al., “Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors,” Sensors, vol. 11, no. 5, pp. 5112–5157, 2011, doi: 10.3390/s110505112.
BibTeX
@article{kasap2011amorphous,
title = {{Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors}},
author = {Kasap, Safa O and Frey, Joel B. and Belev, George S. and Tousignant, Olivier and Mani, H. and Greenspan, J. and Laperrière, Luc and Bubon, Oleksandr and Reznik, Alla and DeCrescenzo, Giovanni and Karim, Karim S. and Rowlands, J. A.},
journal = {Sensors},
year = {2011},
volume = {11},
number = {5},
pages = {5112--5157},
doi = {10.3390/s110505112},
url = {https://doi.org/10.3390/s110505112}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2017 | 31 | |
| 2018 | 23 | |
| 2019 | 41 | |
| 2020 | 49 | |
| 2021 | 53 | |
| 2022 | 48 | |
| 2023 | 57 | |
| 2024 | 53 | |
| 2025 | 58 | |
| 2026 | 47 |
Its field-weighted citation impact is 2.26: it has been cited 2.26 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
- amorphous selenium
- polycrystalline semiconductors
- dark current
- charge trapping
- charge collection efficiency
- detective quantum efficiency
- modulation transfer function
- avalanche multiplication
Work with this paper
Most-cited papers in Medicine
- Yaşlı Kadınlarda Üreme SağlığıDemet Kokanalı, Yaprak Engin Üstün · Jinekoloji-Obstetrik ve Neonatoloji Tıp Dergisi · 2019 · 169,630 citations
- Global Cancer Statistics 2020: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 CountriesHyuna Sung, Adalberto M. Filho, Mathieu Laversanne and 5 more · CA A Cancer Journal for Clinicians · 2021 · 119,885 citations
- “Mini-mental state”Marshal F. Folstein, Susan E. Folstein, Paul R. McHugh · Journal of Psychiatric Research · 1975 · 90,424 citations
- Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countriesFreddie Bray, Jacques Ferlay, Isabelle Soerjomataram and 3 more · CA A Cancer Journal for Clinicians · 2018 · 87,396 citations
- Hallmarks of Cancer: The Next GenerationDouglas Hanahan, Robert A. Weinberg · Cell · 2011 · 69,758 citations
Questions about this paper
How do I cite this paper in APA style?
Kasap, S. O., Frey, J. B., Belev, G. S., Tousignant, O., Mani, H., Greenspan, J., Laperrière, L., Bubon, O., Reznik, A., DeCrescenzo, G., Karim, K. S., & Rowlands, J. A. (2011). Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors. Sensors, 11(5), 5112–5157. https://doi.org/10.3390/s110505112
How many times has this paper been cited?
564 times, according to OpenAlex on 24 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Sensors: sign in and open the full text from this page.
Who wrote this paper?
Safa O Kasap, Joel B. Frey, George S. Belev, Olivier Tousignant, H. Mani, J. Greenspan, Luc Laperrière, Oleksandr Bubon, Alla Reznik, Giovanni DeCrescenzo, Karim S. Karim, J. A. Rowlands.
What is the DOI of this paper?
10.3390/s110505112, permanently at https://doi.org/10.3390/s110505112. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 24 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.