Journal article · 2007 · Open access

Alternative Statistical Parameter for High-Throughput Screening Assay Quality Assessment

Yunxia Sui, Zhijin J. Wu

SLAS DISCOVERY, 12(2), 229–234 · Published 11 January 2007 · DOI 10.1177/1087057106296498

Free PDFView at the publisherCite this paper

In brief

“Alternative Statistical Parameter for High-Throughput Screening Assay Quality Assessment” is a 2007 journal article by Yunxia Sui and Zhijin J. Wu, published in SLAS DISCOVERY. OpenAlex counts 126 citations as of 15 November 2026, which puts it in the top 5% of works published in 2007 by citations. It is open access under a CC BY-NC-ND licence: the full text is free to read at SLAS DISCOVERY.

Citations
126
Most cited in
2021 (14)
Field-weighted impact
2.14
References
6
Authors
2

Abstract

High-throughput screening is an essential process in drug discovery. The ability to identify true active compounds depends on the high quality of assays and proper analysis of data. The Z factor, presented by Zhang et al. in 1999, provides an easy and useful summary of assay quality and has been a widely accepted standard. However, as data analysis has undergone much improvement recently, the assessment of assay quality has not evolved in parallel. In this article, the authors study the implications of Z factor values under different conditions and link the Z factor with the power of discovering true active compounds. They discuss the different interpretations of Z factor depending on error distributions and advocate direct analysis of power as assay quality assessment. They also propose that in estimating assay quality parameters, adjustments in data analysis should be taken into account. Studying the power of identifying true "hits" gives a more direct interpretation of assay quality and may provide guidance in assay optimization on some occasions.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Sui, Y., & Wu, Z. J. (2007). Alternative Statistical Parameter for High-Throughput Screening Assay Quality Assessment. SLAS DISCOVERY, 12(2), 229–234. https://doi.org/10.1177/1087057106296498

MLA 9

Sui, Yunxia, and Zhijin J. Wu. “Alternative Statistical Parameter for High-Throughput Screening Assay Quality Assessment.” SLAS DISCOVERY, vol. 12, no. 2, 2007, pp. 229–234. https://doi.org/10.1177/1087057106296498.

Chicago

Sui, Yunxia and Zhijin J. Wu. 2007. “Alternative Statistical Parameter for High-Throughput Screening Assay Quality Assessment.” SLAS DISCOVERY 12 (2): 229–234. https://doi.org/10.1177/1087057106296498.

Harvard

Sui, Y. and Wu, Z. J. (2007) ‘Alternative Statistical Parameter for High-Throughput Screening Assay Quality Assessment’, SLAS DISCOVERY, 12(2), pp. 229–234. doi:10.1177/1087057106296498.

IEEE

Y. Sui and Z. J. Wu, “Alternative Statistical Parameter for High-Throughput Screening Assay Quality Assessment,” SLAS DISCOVERY, vol. 12, no. 2, pp. 229–234, 2007, doi: 10.1177/1087057106296498.

BibTeX

@article{sui2007alternative,
  title     = {{Alternative Statistical Parameter for High-Throughput Screening Assay Quality Assessment}},
  author    = {Sui, Yunxia and Wu, Zhijin J.},
  journal   = {SLAS DISCOVERY},
  year      = {2007},
  volume    = {12},
  number    = {2},
  pages     = {229--234},
  doi       = {10.1177/1087057106296498},
  url       = {https://doi.org/10.1177/1087057106296498}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201733
201844
201933
20201111
20211414
20221111
202366
202466
202555
202622

Its field-weighted citation impact is 2.14: it has been cited 2.14 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Drug Discovery › Computational Drug Discovery Methods

  • high-throughput screening
  • Z' factor
  • statistical power
  • hit identification
  • error distribution
  • drug discovery
  • assay optimization

Work with this paper

Most-cited papers in Pharmacology, Toxicology and Pharmaceutics

All highly cited Pharmacology, Toxicology and Pharmaceutics papers

Questions about this paper

How do I cite this paper in APA style?

Sui, Y., & Wu, Z. J. (2007). Alternative Statistical Parameter for High-Throughput Screening Assay Quality Assessment. SLAS DISCOVERY, 12(2), 229–234. https://doi.org/10.1177/1087057106296498

How many times has this paper been cited?

126 times, according to OpenAlex on 15 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access: read the free full text at SLAS DISCOVERY.

Who wrote this paper?

Yunxia Sui, Zhijin J. Wu.

What is the DOI of this paper?

10.1177/1087057106296498. The permanent link is https://doi.org/10.1177/1087057106296498.

Bibliographic data from OpenAlex (CC0), last checked 15 November 2026. ResearchGuru does not host this paper; the links go to the publisher or the repository that does.