Review article · 2023 · Open access

Advancing accuracy in guided implant placement: A comprehensive meta-analysis

Anna Takács, Eszter Hardi, Bianca Gólzio Navarro Cavalcante, Bence Szabó, Barbara Kispélyi, Árpád Joób-Fancsaly, Krisztina Mikulás, Gábor Varga, Péter Jenő Hegyi, Márton Kivovics

Journal of Dentistry, 139, 104748 · Published 19 October 2023 · DOI 10.1016/j.jdent.2023.104748

Open full textCite this paper

In brief

“Advancing accuracy in guided implant placement: A comprehensive meta-analysis” is a 2023 review article by Anna Takács and 9 co-authors, published in Journal of Dentistry. OpenAlex counts 41 citations as of 18 November 2026, which puts it in the top 1% of works published in 2023 by citations. It is open access under a CC BY licence: the full text is free to read at Journal of Dentistry.

Citations
41
Most cited in
2025 (17)
Field-weighted impact
1.63
References
276
Authors
10

Abstract

OBJECTIVES: This meta-analysis aimed to determine the accuracy of currently available computer-assisted implant surgery (CAIS) modalities under in vitro conditions and investigate whether these novel techniques can achieve clinically acceptable accuracy. DATA: In vitro studies comparing the postoperative implant position with the preoperative plan were included. Risk of bias was assessed using the Quality Assessment Tool For In Vitro Studies (QUIN Tool) and a sensitivity analysis was conducted using funnel plots. SOURCES: A systematic search was performed on April 18, 2023, using the following three databases: MEDLINE (via PubMed), EMBASE, and Cochrane Central Register of Controlled Trials. No filters or restrictions were applied during the search. RESULTS: A total of 5,894 studies were included following study selection. Robotic- and static CAIS (sCAIS) had the most accurate and clinically acceptable outcomes. sCAIS was further divided according to the guidance level. Among the sCAIS groups, fully guided implant placement had the greatest accuracy. Augmented reality-based CAIS (AR-based CAIS) had clinically acceptable results for all the outcomes except for apical global deviation. Dynamic CAIS (dCAIS) demonstrated clinically safe results, except for horizontal apical deviation. Freehand implant placement was associated with the greatest number of errors. CONCLUSIONS: Fully guided sCAIS demonstrated the most predictable outcomes, whereas freehand sCAIS demonstrated the lowest accuracy. AR-based and robotic CAIS may be promising alternatives. CLINICAL SIGNIFICANCE: To our knowledge, this is the first meta-analysis to evaluate the accuracy of robotic CAIS and investigate the accuracy of various CAIS modalities.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Takács, A., Hardi, E., Cavalcante, B. G. N., Szabó, B., Kispélyi, B., Joób-Fancsaly, Á., Mikulás, K., Varga, G., Hegyi, P. J., & Kivovics, M. (2023). Advancing accuracy in guided implant placement: A comprehensive meta-analysis. Journal of Dentistry, 139, 104748. https://doi.org/10.1016/j.jdent.2023.104748

MLA 9

Takács, Anna, et al. “Advancing accuracy in guided implant placement: A comprehensive meta-analysis.” Journal of Dentistry, vol. 139, 2023, p. 104748. https://doi.org/10.1016/j.jdent.2023.104748.

Chicago

Takács, Anna, Eszter Hardi, Bianca Gólzio Navarro Cavalcante, Bence Szabó, Barbara Kispélyi, Árpád Joób-Fancsaly, Krisztina Mikulás, Gábor Varga, Péter Jenő Hegyi, and Márton Kivovics. 2023. “Advancing accuracy in guided implant placement: A comprehensive meta-analysis.” Journal of Dentistry 139: 104748. https://doi.org/10.1016/j.jdent.2023.104748.

Harvard

Takács, A. et al. (2023) ‘Advancing accuracy in guided implant placement: A comprehensive meta-analysis’, Journal of Dentistry, 139, p. 104748. doi:10.1016/j.jdent.2023.104748.

IEEE

A. Takács et al., “Advancing accuracy in guided implant placement: A comprehensive meta-analysis,” Journal of Dentistry, vol. 139, p. 104748, 2023, doi: 10.1016/j.jdent.2023.104748.

BibTeX

@article{takacs2023advancing,
  title     = {{Advancing accuracy in guided implant placement: A comprehensive meta-analysis}},
  author    = {Takács, Anna and Hardi, Eszter and Cavalcante, Bianca Gólzio Navarro and Szabó, Bence and Kispélyi, Barbara and Joób-Fancsaly, Árpád and Mikulás, Krisztina and Varga, Gábor and Hegyi, Péter Jenő and Kivovics, Márton},
  journal   = {Journal of Dentistry},
  year      = {2023},
  volume    = {139},
  pages     = {104748},
  doi       = {10.1016/j.jdent.2023.104748},
  url       = {https://doi.org/10.1016/j.jdent.2023.104748}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
20241414
20251717
20261010

Its field-weighted citation impact is 1.63: it has been cited 1.63 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes

  • computer-assisted implant surgery
  • dental implant placement accuracy
  • freehand implant placement
  • apical deviation

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Takács, A., Hardi, E., Cavalcante, B. G. N., Szabó, B., Kispélyi, B., Joób-Fancsaly, Á., Mikulás, K., Varga, G., Hegyi, P. J., & Kivovics, M. (2023). Advancing accuracy in guided implant placement: A comprehensive meta-analysis. Journal of Dentistry, 139, 104748. https://doi.org/10.1016/j.jdent.2023.104748

How many times has this paper been cited?

41 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Journal of Dentistry: sign in and open the full text from this page.

Who wrote this paper?

Anna Takács, Eszter Hardi, Bianca Gólzio Navarro Cavalcante, Bence Szabó, Barbara Kispélyi, Árpád Joób-Fancsaly, Krisztina Mikulás, Gábor Varga, Péter Jenő Hegyi, Márton Kivovics.

What is the DOI of this paper?

10.1016/j.jdent.2023.104748, permanently at https://doi.org/10.1016/j.jdent.2023.104748. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.