Review article · 2025 · Open access

Accuracy of static and dynamic computer-aided implant surgery for immediate implant placement: A systematic review and meta-analysis

Katherine Lau, Tommy Kok Chu Fung, Dominic King Lun Ho, George Pelekos, Melissa Rachel Fok

Journal of Prosthodontic Research, 69(4), 472–488 · Published 18 November 2025 · DOI 10.2186/jpr.jpr_d_24_00257

Open PDFView at the publisherCite this paper

In brief

“Accuracy of static and dynamic computer-aided implant surgery for immediate implant placement: A systematic review and meta-analysis” is a 2025 review article by Katherine Lau and 4 co-authors, published in Journal of Prosthodontic Research. OpenAlex counts 12 citations as of 18 November 2026, which puts it in the top 5% of works published in 2025 by citations. It is open access under a CC BY-NC licence: the full text is free to read at Journal of Prosthodontic Research.

Citations
12
Most cited in
2026 (9)
Field-weighted impact
1.78
References
61
Authors
5

Abstract

PURPOSE: To investigate the accuracy of static and dynamic computer-aided implant surgery (s/d-CAIS) for immediate implant placement for single-tooth replacement in healthy individuals with partially edentulous zones. STUDY SELECTION: A systematic search of six electronic databases for clinical studies reporting on Type 1 implant placement identified 15 eligible articles (seven RCTs, two prospective studies, and six retrospective studies) involving 383 patients. The focus question addressed population, intervention, comparison, and outcome criteria. A meta-analysis was performed using a random-effects model to obtain pooled estimates, presented as forest plots with weighted mean differences and 95% confidence intervals. Quality assessment was conducted using the Robin-I and RoB2 tools. RESULTS: The meta-analysis revealed that s/d-CAIS demonstrated significantly lower global platform and apex deviation compared to freehand placement, with mean differences of -0.70 mm (95% CI -0.74, -0.66; P < 0.001) and -0.86 mm (95% CI -1.00, -0.73; P < 0.001) respectively. The mean difference in platform depth deviation was statistically significant in favor of CAIS, with a mean difference of -0.73 mm (95% CI -1.04, -0.43; P < 0.001). High heterogeneity was observed across studies. The average global coronal, global apex, and angulation deviation for d-CAIS and s-CAIS were 0.72 mm, 0.81 mm, and 2.04 degrees, and 0.80 mm, 1.10 mm, and 2.12 degrees, respectively. CONCLUSIONS: Data on Type 1 implant placement suggest that s/d-CAIS may enhance implant placement accuracy in several dimensions compared with freehand placement, with d-CAIS demonstrating marginally better control over angulation. However, the high heterogeneity across studies with a moderate-to-high risk of bias limits the generalizability of these findings.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Lau, K., Fung, T. K. C., Ho, D. K. L., Pelekos, G., & Fok, M. R. (2025). Accuracy of static and dynamic computer-aided implant surgery for immediate implant placement: A systematic review and meta-analysis. Journal of Prosthodontic Research, 69(4), 472–488. https://doi.org/10.2186/jpr.jpr_d_24_00257

MLA 9

Lau, Katherine, et al. “Accuracy of static and dynamic computer-aided implant surgery for immediate implant placement: A systematic review and meta-analysis.” Journal of Prosthodontic Research, vol. 69, no. 4, 2025, pp. 472–488. https://doi.org/10.2186/jpr.jpr_d_24_00257.

Chicago

Lau, Katherine, Tommy Kok Chu Fung, Dominic King Lun Ho, George Pelekos, and Melissa Rachel Fok. 2025. “Accuracy of static and dynamic computer-aided implant surgery for immediate implant placement: A systematic review and meta-analysis.” Journal of Prosthodontic Research 69 (4): 472–488. https://doi.org/10.2186/jpr.jpr_d_24_00257.

Harvard

Lau, K. et al. (2025) ‘Accuracy of static and dynamic computer-aided implant surgery for immediate implant placement: A systematic review and meta-analysis’, Journal of Prosthodontic Research, 69(4), pp. 472–488. doi:10.2186/jpr.jpr_d_24_00257.

IEEE

K. Lau, T. K. C. Fung, D. K. L. Ho, G. Pelekos, and M. R. Fok, “Accuracy of static and dynamic computer-aided implant surgery for immediate implant placement: A systematic review and meta-analysis,” Journal of Prosthodontic Research, vol. 69, no. 4, pp. 472–488, 2025, doi: 10.2186/jpr.jpr_d_24_00257.

BibTeX

@article{lau2025accuracy,
  title     = {{Accuracy of static and dynamic computer-aided implant surgery for immediate implant placement: A systematic review and meta-analysis}},
  author    = {Lau, Katherine and Fung, Tommy Kok Chu and Ho, Dominic King Lun and Pelekos, George and Fok, Melissa Rachel},
  journal   = {Journal of Prosthodontic Research},
  year      = {2025},
  volume    = {69},
  number    = {4},
  pages     = {472--488},
  doi       = {10.2186/jpr.jpr_d_24_00257},
  url       = {https://doi.org/10.2186/jpr.jpr_d_24_00257}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes

  • computer-aided implant surgery
  • immediate implant placement
  • single-tooth replacement
  • implant placement accuracy
  • freehand implant placement
  • implant angulation

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Lau, K., Fung, T. K. C., Ho, D. K. L., Pelekos, G., & Fok, M. R. (2025). Accuracy of static and dynamic computer-aided implant surgery for immediate implant placement: A systematic review and meta-analysis. Journal of Prosthodontic Research, 69(4), 472–488. https://doi.org/10.2186/jpr.jpr_d_24_00257

How many times has this paper been cited?

12 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Journal of Prosthodontic Research: sign in and open the PDF from this page.

Who wrote this paper?

Katherine Lau, Tommy Kok Chu Fung, Dominic King Lun Ho, George Pelekos, Melissa Rachel Fok.

What is the DOI of this paper?

10.2186/jpr.jpr_d_24_00257, permanently at https://doi.org/10.2186/jpr.jpr_d_24_00257. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.