Journal article · 2021 · Open access

Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study

Bowen Ma, Xinxin Yue, Yujie Sun, Lingyan Peng, Wei Geng

BMC Oral Health, 21(1), 636 · Published 1 December 2021 · DOI 10.1186/s12903-021-02005-0

Open PDFView at the publisherCite this paper

In brief

“Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study” is a 2021 journal article by Bowen Ma and 4 co-authors, published in BMC Oral Health. OpenAlex counts 147 citations as of 27 November 2026, which puts it in the top 3% of works published in 2021 by citations. It is open access under a CC BY licence: the full text is free to read at BMC Oral Health.

Citations
147
Most cited in
2026 (52)
Field-weighted impact
10.40
References
42
Authors
5

Abstract

BACKGROUND: To compare the accuracy of photogrammetry, intraoral scanning and conventional impression techniques for complete-arch implant rehabilitation. METHODS: A master cast containing 6 implant abutment replicas was fabricated. Group PG: digital impressions were taken 10 times using a photogrammetry system; Group IOS: intraoral scanning was performed to fabricate 10 digital impressions; Group CNV: splinted open-tray impression technique was used to fabricate 10 definitive casts. The master cast and conventional definitive casts were digitized with a laboratory reference scanner. For all STL files obtained, scan bodies were converted to implant abutment replicas using a digital library. The accuracy of a digitizer was defined by 2 main parameters, trueness and precision. "Trueness" was used to describe the deviation between test files and reference file, and "precision" was used to describe the closeness between test files. Then, the trueness and precision of three impression techniques were evaluated and statistically compared (α = 0.05). RESULTS: The median trueness was 24.45, 43.45 and 28.70 μm for group PG, IOS and CNV; Group PG gave more accurate trueness than group IOS (P < 0.001) and group CNV (P = 0.033), group CNV showed more accurate trueness than group IOS (P = 0.033). The median precision was 2.00, 36.00 and 29.40 μm for group PG, IOS and CNV; Group PG gave more accurate precision than group IOS (P < 0.001) and group CNV (P < 0.001), group CNV showed more accurate precision than IOS (P = 0.002). CONCLUSIONS: For complete-arch implant rehabilitation, the photogrammetry system showed the best accuracy of all the impression techniques evaluated, followed by the conventional impression technique, and the intraoral scanner provided the least accuracy.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Ma, B., Yue, X., Sun, Y., Peng, L., & Geng, W. (2021). Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study. BMC Oral Health, 21(1), 636. https://doi.org/10.1186/s12903-021-02005-0

MLA 9

Ma, Bowen, et al. “Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study.” BMC Oral Health, vol. 21, no. 1, 2021, p. 636. https://doi.org/10.1186/s12903-021-02005-0.

Chicago

Ma, Bowen, Xinxin Yue, Yujie Sun, Lingyan Peng, and Wei Geng. 2021. “Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study.” BMC Oral Health 21 (1): 636. https://doi.org/10.1186/s12903-021-02005-0.

Harvard

Ma, B. et al. (2021) ‘Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study’, BMC Oral Health, 21(1), p. 636. doi:10.1186/s12903-021-02005-0.

IEEE

B. Ma, X. Yue, Y. Sun, L. Peng, and W. Geng, “Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study,” BMC Oral Health, vol. 21, no. 1, p. 636, 2021, doi: 10.1186/s12903-021-02005-0.

BibTeX

@article{ma2021accuracy,
  title     = {{Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study}},
  author    = {Ma, Bowen and Yue, Xinxin and Sun, Yujie and Peng, Lingyan and Geng, Wei},
  journal   = {BMC Oral Health},
  year      = {2021},
  volume    = {21},
  number    = {1},
  pages     = {636},
  doi       = {10.1186/s12903-021-02005-0},
  url       = {https://doi.org/10.1186/s12903-021-02005-0}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
202255
20231515
20243030
20254545
20265252

Its field-weighted citation impact is 10.40: it has been cited 10.40 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes

  • photogrammetry
  • intraoral scanning
  • dental impression accuracy
  • trueness and precision
  • open tray impression
  • digital impressions
  • STL files

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Ma, B., Yue, X., Sun, Y., Peng, L., & Geng, W. (2021). Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study. BMC Oral Health, 21(1), 636. https://doi.org/10.1186/s12903-021-02005-0

How many times has this paper been cited?

147 times, according to OpenAlex on 27 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at BMC Oral Health: sign in and open the PDF from this page.

Who wrote this paper?

Bowen Ma, Xinxin Yue, Yujie Sun, Lingyan Peng, Wei Geng.

What is the DOI of this paper?

10.1186/s12903-021-02005-0, permanently at https://doi.org/10.1186/s12903-021-02005-0. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 27 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.