Review article · 2025 · Open access
Accuracy of Navigation and Robot-Assisted Systems for Dental Implant Placement: A Systematic Review
Dentistry Journal, 13(11), 537 · Published 14 November 2025 · DOI 10.3390/dj13110537
In brief
“Accuracy of Navigation and Robot-Assisted Systems for Dental Implant Placement: A Systematic Review” is a 2025 review article by Daria Pisla and 8 co-authors, published in Dentistry Journal. OpenAlex counts 13 citations as of 18 November 2026. It is open access under a CC BY licence: the full text is free to read at Dentistry Journal.
- Citations
- 13
- Most cited in
- 2026 (12)
- Field-weighted impact
- 2.10
- References
- 52
- Authors
- 9
Abstract
Background: Computer-assisted implant surgery (CAIS) aims to improve placement accuracy versus freehand drilling. We compared the three-dimensional accuracy of robot-guided CAIS (r-CAIS), dynamic navigation (d-CAIS), static-template guidance (s-CAIS), and freehand (FH) in clinical and in vitro settings. Methods: We searched PubMed/MEDLINE, Scopus, and Web of Science (1 January 2019–2025). Eligible populations were adults receiving conventional or zygomatic implants in vivo, plus validated in vitro human-jaw models using plan-versus-placement workflows; studies had to report study-level means with dispersion for ≥1 primary outcome with ≥5 implants per arm. Interventions were r-CAIS, d-CAIS, or s-CAIS; with a baseline as the freehand technique. Risk of bias used RoB 2 (RCTs), ROBINS-I (non-randomized clinical), and QUIN (in vitro). Because of heterogeneity in definitions and workflows, we performed a descriptive synthesis by modality (no meta-analysis). Registration: OSF. Results: Forty-three studies (7 RCTs, 10 non-randomized clinical, 26 in vitro) reported more than 4000 implants. Across studies, typical study-level means for global linear deviation clustered around < 1 mm (r-CAIS), ~1 mm (d-CAIS), ~1.3 mm (s-CAIS), and ~1.8 mm (FH). In clinical contexts, d-CAIS often showed slightly lower angular deviation than s-CAIS. Conclusions: CAIS improves accuracy versus freehand. d-CAIS and s-CAIS show similar linear accuracy, with d-CAIS frequently yielding slightly lower angular deviation; r-CAIS exhibits tight error clusters in our dataset, but limited comparative clinical evidence precludes superiority claims. Limitations: non-uniform registration/measurement, variable operator experience, and absence of meta-analysis.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Pisla, D., Bulbucan, V., Hedesiu, M. C., Vaida, C. L., Pusca, A., Mocan, R., Tucan, P., Dinu, C. M., & Pisla, D. L. (2025). Accuracy of Navigation and Robot-Assisted Systems for Dental Implant Placement: A Systematic Review. Dentistry Journal, 13(11), 537. https://doi.org/10.3390/dj13110537
MLA 9
Pisla, Daria, et al. “Accuracy of Navigation and Robot-Assisted Systems for Dental Implant Placement: A Systematic Review.” Dentistry Journal, vol. 13, no. 11, 2025, p. 537. https://doi.org/10.3390/dj13110537.
Chicago
Pisla, Daria, Vasile Bulbucan, Mihaela Carmen Hedesiu, Calin Liviu Vaida, Alexandru Pusca, Rares Mocan, Paul Tucan, Cristian Mihail Dinu, and Doina Liana Pisla. 2025. “Accuracy of Navigation and Robot-Assisted Systems for Dental Implant Placement: A Systematic Review.” Dentistry Journal 13 (11): 537. https://doi.org/10.3390/dj13110537.
Harvard
Pisla, D. et al. (2025) ‘Accuracy of Navigation and Robot-Assisted Systems for Dental Implant Placement: A Systematic Review’, Dentistry Journal, 13(11), p. 537. doi:10.3390/dj13110537.
IEEE
D. Pisla et al., “Accuracy of Navigation and Robot-Assisted Systems for Dental Implant Placement: A Systematic Review,” Dentistry Journal, vol. 13, no. 11, p. 537, 2025, doi: 10.3390/dj13110537.
BibTeX
@article{pisla2025accuracy,
title = {{Accuracy of Navigation and Robot-Assisted Systems for Dental Implant Placement: A Systematic Review}},
author = {Pisla, Daria and Bulbucan, Vasile and Hedesiu, Mihaela Carmen and Vaida, Calin Liviu and Pusca, Alexandru and Mocan, Rares and Tucan, Paul and Dinu, Cristian Mihail and Pisla, Doina Liana},
journal = {Dentistry Journal},
year = {2025},
volume = {13},
number = {11},
pages = {537},
doi = {10.3390/dj13110537},
url = {https://doi.org/10.3390/dj13110537}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- dental implant surgery
- computer-assisted implant surgery
- dynamic navigation
- implant placement accuracy
- zygomatic implants
- linear deviation
- angular deviation
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Pisla, D., Bulbucan, V., Hedesiu, M. C., Vaida, C. L., Pusca, A., Mocan, R., Tucan, P., Dinu, C. M., & Pisla, D. L. (2025). Accuracy of Navigation and Robot-Assisted Systems for Dental Implant Placement: A Systematic Review. Dentistry Journal, 13(11), 537. https://doi.org/10.3390/dj13110537
How many times has this paper been cited?
13 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Dentistry Journal: sign in and open the PDF from this page.
Who wrote this paper?
Daria Pisla, Vasile Bulbucan, Mihaela Carmen Hedesiu, Calin Liviu Vaida, Alexandru Pusca, Rares Mocan, Paul Tucan, Cristian Mihail Dinu, Doina Liana Pisla.
What is the DOI of this paper?
10.3390/dj13110537, permanently at https://doi.org/10.3390/dj13110537. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.