Journal article · 2023 · Open access

Accuracy of immediate dental implant placement with task‐autonomous robotic system and navigation system: An in vitro study

Jinyan Chen, Minjie Zhuang, Baoxin Tao, Yiqun Wu, Lijuan Ye, Feng Wang

Clinical Oral Implants Research, 35(8), 973–983 · Published 29 May 2023 · DOI 10.1111/clr.14104

Open PDFView at the publisherCite this paper

In brief

“Accuracy of immediate dental implant placement with task‐autonomous robotic system and navigation system: An in vitro study” is a 2023 journal article by Jinyan Chen and 5 co-authors, published in Clinical Oral Implants Research. OpenAlex counts 66 citations as of 28 November 2026, which puts it in the top 4% of works published in 2023 by citations. It is open access: the full text is free to read at Clinical Oral Implants Research.

Citations
66
Most cited in
2024 (23)
Field-weighted impact
11.72
References
40
Authors
6

Abstract

OBJECTIVES: The aim of this study was to compare the accuracy of dental implant placement in a single tooth gap, including the postextraction site and healed site, using a task-autonomous robotic system and a dynamic navigation system. MATERIALS AND METHODS: Forty partially edentulous models requiring both immediate and conventional implant placement were randomly divided into a robotic system group and a navigation system group. The coronal, apical, and angular deviations of the implants were measured and assessed between the groups. RESULTS: The deviations in immediate implant placement were compared between the robotic system and dynamic navigation system groups, showing a mean (±SD) coronal deviation of 0.86 ± 0.36 versus 0.70 ± 0.21 mm (p = .101), a mean apical deviation of 0.77 ± 0.34 versus 0.95 ± 0.38 mm (p = .127), and a mean angular deviation of 1.94 ± 0.66° versus 3.44 ± 1.38° (p < .001). At the healed site, significantly smaller coronal deviation (0.46 ± 0.29 vs. 0.70 ± 0.30 mm, p = .005), apical deviation (0.56 ± 0.30 vs. 0.85 ± 0.25 mm, p < .001), and angular deviation (1.36 ± 0.54 vs. 1.80 ± 0.70 mm, p = .034) were found in the robotic system group than in the dynamic navigation group. CONCLUSIONS: The position in both immediate and conventional implant placement was more precise with the task-autonomous robotic system than with the dynamic navigation system. Its performance in actual clinical applications should be confirmed in further trials.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Chen, J., Zhuang, M., Tao, B., Wu, Y., Ye, L., & Wang, F. (2023). Accuracy of immediate dental implant placement with task‐autonomous robotic system and navigation system: An in vitro study. Clinical Oral Implants Research, 35(8), 973–983. https://doi.org/10.1111/clr.14104

MLA 9

Chen, Jinyan, et al. “Accuracy of immediate dental implant placement with task‐autonomous robotic system and navigation system: An in vitro study.” Clinical Oral Implants Research, vol. 35, no. 8, 2023, pp. 973–983. https://doi.org/10.1111/clr.14104.

Chicago

Chen, Jinyan, Minjie Zhuang, Baoxin Tao, Yiqun Wu, Lijuan Ye, and Feng Wang. 2023. “Accuracy of immediate dental implant placement with task‐autonomous robotic system and navigation system: An in vitro study.” Clinical Oral Implants Research 35 (8): 973–983. https://doi.org/10.1111/clr.14104.

Harvard

Chen, J. et al. (2023) ‘Accuracy of immediate dental implant placement with task‐autonomous robotic system and navigation system: An in vitro study’, Clinical Oral Implants Research, 35(8), pp. 973–983. doi:10.1111/clr.14104.

IEEE

J. Chen, M. Zhuang, B. Tao, Y. Wu, L. Ye, and F. Wang, “Accuracy of immediate dental implant placement with task‐autonomous robotic system and navigation system: An in vitro study,” Clinical Oral Implants Research, vol. 35, no. 8, pp. 973–983, 2023, doi: 10.1111/clr.14104.

BibTeX

@article{chen2023accuracy,
  title     = {{Accuracy of immediate dental implant placement with task‐autonomous robotic system and navigation system: An in vitro study}},
  author    = {Chen, Jinyan and Zhuang, Minjie and Tao, Baoxin and Wu, Yiqun and Ye, Lijuan and Wang, Feng},
  journal   = {Clinical Oral Implants Research},
  year      = {2023},
  volume    = {35},
  number    = {8},
  pages     = {973--983},
  doi       = {10.1111/clr.14104},
  url       = {https://doi.org/10.1111/clr.14104}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
202344
20242323
20252323
20261616

Its field-weighted citation impact is 11.72: it has been cited 11.72 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes

  • immediate implant placement
  • dynamic navigation system
  • implant placement accuracy
  • coronal deviation
  • apical deviation
  • angular deviation

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Chen, J., Zhuang, M., Tao, B., Wu, Y., Ye, L., & Wang, F. (2023). Accuracy of immediate dental implant placement with task‐autonomous robotic system and navigation system: An in vitro study. Clinical Oral Implants Research, 35(8), 973–983. https://doi.org/10.1111/clr.14104

How many times has this paper been cited?

66 times, according to OpenAlex on 28 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Clinical Oral Implants Research: sign in and open the PDF from this page.

Who wrote this paper?

Jinyan Chen, Minjie Zhuang, Baoxin Tao, Yiqun Wu, Lijuan Ye, Feng Wang.

What is the DOI of this paper?

10.1111/clr.14104, permanently at https://doi.org/10.1111/clr.14104. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 28 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.