Journal article · 2024 · Open access

Accuracy of edentulous full‐arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry

Jing Qiu Cheng, Haidong Zhang, Hailin Liu, Junying Li, Hom‐Lay Wang, Xian Tao

Clinical Oral Implants Research, 35(5), 560–572 · Published 29 February 2024 · DOI 10.1111/clr.14252

Open PDFView at the publisherCite this paper

In brief

“Accuracy of edentulous full‐arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry” is a 2024 journal article by Jing Qiu Cheng and 5 co-authors, published in Clinical Oral Implants Research. OpenAlex counts 110 citations as of 25 November 2026, which puts it in the top 1% of works published in 2024 by citations. It is open access under a CC BY-NC-ND licence: the full text is free to read at Clinical Oral Implants Research.

Citations
110
Most cited in
2026 (57)
Field-weighted impact
30.20
References
68
Authors
6

Abstract

OBJECTIVES: The purpose of this in vitro study was to compare the trueness and precision of complete arch implant impressions using conventional impression, intraoral scanning with and without splinting, and stereophotogrammetry. MATERIALS AND METHODS: An edentulous model with six implants was used in this study. Four implant impression techniques were compared: the conventional impression (CI), intraoral scanning (IOS) without splinting, intraoral scanning with splinting (MIOS), and stereophotogrammetry (SPG). An industrial blue light scanner was used to generate the baseline scan from the model. The CI was captured with a laboratory scanner. The reference best-fit method was then applied in the computer-aided design (CAD) software to compute the three-dimensional, angular, and linear discrepancies among the four impression techniques. The root mean square (RMS) 3D discrepancies in trueness and precision between the four impression groups were analyzed with a Kruskal-Wallis test. Trueness and precision between single analogs were assessed using generalized estimating equations. RESULTS: Significant differences in the overall trueness (p = .017) and precision (p < .001) were observed across four impression groups. The SPG group exhibited significantly smaller RMS 3D deviations than the CI, IOS, and MIOS groups (p < .05), with no significant difference detected among the latter three groups (p > .05). CONCLUSIONS: Stereophotogrammetry showed superior trueness and precision, meeting misfit thresholds for implant-supported complete arch prostheses. Intraoral scanning, while accurate like conventional impressions, exhibited cross-arch angular and linear deviations. Adding a splint to the scan body did not improve intraoral scanning accuracy.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Cheng, J. Q., Zhang, H., Liu, H., Li, J., Wang, H., & Tao, X. (2024). Accuracy of edentulous full‐arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry. Clinical Oral Implants Research, 35(5), 560–572. https://doi.org/10.1111/clr.14252

MLA 9

Cheng, Jing Qiu, et al. “Accuracy of edentulous full‐arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry.” Clinical Oral Implants Research, vol. 35, no. 5, 2024, pp. 560–572. https://doi.org/10.1111/clr.14252.

Chicago

Cheng, Jing Qiu, Haidong Zhang, Hailin Liu, Junying Li, Hom‐Lay Wang, and Xian Tao. 2024. “Accuracy of edentulous full‐arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry.” Clinical Oral Implants Research 35 (5): 560–572. https://doi.org/10.1111/clr.14252.

Harvard

Cheng, J. Q. et al. (2024) ‘Accuracy of edentulous full‐arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry’, Clinical Oral Implants Research, 35(5), pp. 560–572. doi:10.1111/clr.14252.

IEEE

J. Q. Cheng, H. Zhang, H. Liu, J. Li, H. Wang, and X. Tao, “Accuracy of edentulous full‐arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry,” Clinical Oral Implants Research, vol. 35, no. 5, pp. 560–572, 2024, doi: 10.1111/clr.14252.

BibTeX

@article{cheng2024accuracy,
  title     = {{Accuracy of edentulous full‐arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry}},
  author    = {Cheng, Jing Qiu and Zhang, Haidong and Liu, Hailin and Li, Junying and Wang, Hom‐Lay and Tao, Xian},
  journal   = {Clinical Oral Implants Research},
  year      = {2024},
  volume    = {35},
  number    = {5},
  pages     = {560--572},
  doi       = {10.1111/clr.14252},
  url       = {https://doi.org/10.1111/clr.14252}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
20241313
20254040
20265757

Its field-weighted citation impact is 30.20: it has been cited 30.20 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes

  • stereophotogrammetry
  • intraoral scanning
  • conventional impressions
  • splinting
  • trueness and precision
  • 3D deviation

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Cheng, J. Q., Zhang, H., Liu, H., Li, J., Wang, H., & Tao, X. (2024). Accuracy of edentulous full‐arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry. Clinical Oral Implants Research, 35(5), 560–572. https://doi.org/10.1111/clr.14252

How many times has this paper been cited?

110 times, according to OpenAlex on 25 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Clinical Oral Implants Research: sign in and open the PDF from this page.

Who wrote this paper?

Jing Qiu Cheng, Haidong Zhang, Hailin Liu, Junying Li, Hom‐Lay Wang, Xian Tao.

What is the DOI of this paper?

10.1111/clr.14252, permanently at https://doi.org/10.1111/clr.14252. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 25 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.