Journal article · 2026 · Open access

Accuracy of complete‐arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry

Richard Lee, Darren Littlefair, Dale G. Howes

Journal of Prosthodontics · Published 9 October 2026 · DOI 10.1111/jopr.70249

Open full textCite this paper

In brief

“Accuracy of complete‐arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry” is a 2026 journal article by Richard Lee and 2 co-authors, published in Journal of Prosthodontics. OpenAlex counts 0 citations as of 18 November 2026. It is open access under a CC BY licence: the full text is free to read at Journal of Prosthodontics.

Citations
0
References
31
Authors
3

Abstract

PURPOSE: The purpose of this in vitro study was to compare the accuracy of analog impressions, intraoral scanning, extraoral photogrammetry, and intraoral photogrammetry in recording complete-arch implant positions. MATERIALS AND METHODS: A stainless-steel reference model representing an edentulous maxilla with six parallel implants and multiunit abutments was tested using two analog impression techniques; seven intraoral scanners with vertical scan bodies: Omnicam, Primescan, Trios 3, Trios 4, Trios 5, i700, and Aoralscan 3; three extraoral photogrammetry systems: PIC, iCam4D, and Tupel 3D; and one intraoral photogrammetry system: Aoralscan Elite (n = 10 per group). A coordinate-measuring machine measured the abutment center positions and axes on the reference model and analog stone casts, and a computer-aided design program measured the intraoral scanning and photogrammetry digital files. The inter-abutment distances and angles were compared to determine the accuracy of each technique. RESULTS: The analog groups recorded linear trueness of 39-47 µm (precision 17-18 µm) and angular trueness of 0.07°-0.08° (precision 0.02°-0.05°). The intraoral scanning groups recorded linear trueness of 78-141 µm (precision 18-83 µm) and angular trueness of 0.23°-0.71° (precision 0.05°-0.24°). The extraoral photogrammetry groups recorded linear trueness of 53-77 µm (precision 2-30 µm) and angular trueness of 0.22°-0.57° (precision 0.01°-0.05°). The intraoral photogrammetry recorded linear trueness of 15 µm (precision 6 µm) and angular trueness of 0.11° (precision 0.02°). CONCLUSIONS: Intraoral scanning demonstrated deviations (mean 101 µm) over twice that of analog impressions (mean 43 µm), while extraoral photogrammetry (mean 62 µm) and intraoral photogrammetry (mean 15 µm) demonstrated accuracy comparable or superior to analog impressions.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Lee, R., Littlefair, D., & Howes, D. G. (2026). Accuracy of complete‐arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70249

MLA 9

Lee, Richard, et al. “Accuracy of complete‐arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry.” Journal of Prosthodontics, 2026. https://doi.org/10.1111/jopr.70249.

Chicago

Lee, Richard, Darren Littlefair, and Dale G. Howes. 2026. “Accuracy of complete‐arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry.” Journal of Prosthodontics. https://doi.org/10.1111/jopr.70249.

Harvard

Lee, R., Littlefair, D. and Howes, D. G. (2026) ‘Accuracy of complete‐arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry’, Journal of Prosthodontics. doi:10.1111/jopr.70249.

IEEE

R. Lee, D. Littlefair, and D. G. Howes, “Accuracy of complete‐arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry,” Journal of Prosthodontics, 2026, doi: 10.1111/jopr.70249.

BibTeX

@article{lee2026accuracy,
  title     = {{Accuracy of complete‐arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry}},
  author    = {Lee, Richard and Littlefair, Darren and Howes, Dale G.},
  journal   = {Journal of Prosthodontics},
  year      = {2026},
  doi       = {10.1111/jopr.70249},
  url       = {https://doi.org/10.1111/jopr.70249}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes

  • dental implant planning
  • intraoral scanning
  • edentulous maxilla
  • coordinate measuring machine
  • computer-aided design
  • 3D imaging

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Lee, R., Littlefair, D., & Howes, D. G. (2026). Accuracy of complete‐arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70249

How many times has this paper been cited?

0 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Journal of Prosthodontics: sign in and open the full text from this page.

Who wrote this paper?

Richard Lee, Darren Littlefair, Dale G. Howes.

What is the DOI of this paper?

10.1111/jopr.70249, permanently at https://doi.org/10.1111/jopr.70249. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.