Journal article · 2025 · Open access
Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study
Clinical Oral Implants Research, 36(8), 991–999 · Published 7 May 2025 · DOI 10.1111/clr.14445
In brief
“Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study” is a 2025 journal article by X J Fu and 6 co-authors, published in Clinical Oral Implants Research. OpenAlex counts 27 citations as of 18 November 2026, which puts it in the top 2% of works published in 2025 by citations. It is open access: the full text is free to read at Clinical Oral Implants Research.
- Citations
- 27
- Most cited in
- 2026 (20)
- Field-weighted impact
- 18.95
- References
- 33
- Authors
- 7
Abstract
OBJECTIVES: To compare the accuracy of complete-arch implant impressions using four digital techniques: extraoral photogrammetry (EPG), intraoral scanning with original scan body (IOS), intraoral scanning with prefabricated aids (IOSA), and intraoral photogrammetry (IPG). MATERIALS AND METHODS: One edentulous maxillary master model with six parallel abutment analogs was scanned by a laboratory scanner as the reference scan. EPG, IOS, IOSA, and IPG were used to scan the master model with respective scan bodies as test scans. Ten scanning data were gained for each technique. Trueness and precision of root mean square (RMS) errors were measured between the test and reference scans. Deviations in distance and angle relative to the reference scan between all pairs of abutment analogs were measured. Scanning time was recorded. RESULTS: IPG showed significantly best trueness in RMS errors (IPG, 26.37 ± 1.02 μm; EPG, 31.72 ± 0.59 μm; IOS, 39.93 ± 7.98 μm; IOSA, 50.60 ± 12.46 μm), (all p < 0.050). EPG showed significantly best precision in RMS errors (EPG, 2.30 ± 1.31 μm; IPG, 4.12 ± 0.87 μm; IOS, 33.38 ± 13.95 μm; IOSA, 28.35 ± 11.48 μm), (all p < 0.001). IPG demonstrated significantly best performance in distance deviation (IPG, 28.59 ± 24.75 μm; EPG, 55.55 ± 37.82 μm; IOS, 62.97 ± 50.60 μm; IOSA, 93.37 ± 72.15 μm), (all p < 0.050). No significant differences were found regarding angle deviation (p = 0.313). IOSA showed the longest scanning duration (IPG: 50.30 ± 6.77 s; EPG: 57.40 ± 5.19 s; IOS: 91.10 ± 20.31 s; IOSA: 125.00 ± 18.74 s), (all p < 0.001). CONCLUSIONS: IPG achieved comparable accuracy with EPG in complete-arch implant digital impressions in vitro. IPG offers an efficient and straightforward workflow, making it a valuable alternative method; however, further clinical studies are needed to validate its efficacy.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Fu, X. J., Cai, Z., Shi, J., Qiao, S., Tonetti, M. S., Lai, H., & Liu, B. (2025). Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study. Clinical Oral Implants Research, 36(8), 991–999. https://doi.org/10.1111/clr.14445
MLA 9
Fu, X J, et al. “Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study.” Clinical Oral Implants Research, vol. 36, no. 8, 2025, pp. 991–999. https://doi.org/10.1111/clr.14445.
Chicago
Fu, X J, Zheng‐Zhen Cai, Junyu Shi, Shichong Qiao, Maurizio S. Tonetti, Hong‐Chang Lai, and Bei‐Lei Liu. 2025. “Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study.” Clinical Oral Implants Research 36 (8): 991–999. https://doi.org/10.1111/clr.14445.
Harvard
Fu, X. J. et al. (2025) ‘Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study’, Clinical Oral Implants Research, 36(8), pp. 991–999. doi:10.1111/clr.14445.
IEEE
X. J. Fu et al., “Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study,” Clinical Oral Implants Research, vol. 36, no. 8, pp. 991–999, 2025, doi: 10.1111/clr.14445.
BibTeX
@article{fu2025accuracy,
title = {{Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study}},
author = {Fu, X J and Cai, Zheng‐Zhen and Shi, Junyu and Qiao, Shichong and Tonetti, Maurizio S. and Lai, Hong‐Chang and Liu, Bei‐Lei},
journal = {Clinical Oral Implants Research},
year = {2025},
volume = {36},
number = {8},
pages = {991--999},
doi = {10.1111/clr.14445},
url = {https://doi.org/10.1111/clr.14445}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Topic and keywords
Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- digital dental impressions
- intraoral scanning
- edentulous maxilla
- trueness and precision
- scanning accuracy
- scan time
- master model
- implant-supported prostheses
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Fu, X. J., Cai, Z., Shi, J., Qiao, S., Tonetti, M. S., Lai, H., & Liu, B. (2025). Accuracy of a Novel Intraoral Photogrammetry Technique for Complete‐Arch Implant Impressions: An In Vitro Study. Clinical Oral Implants Research, 36(8), 991–999. https://doi.org/10.1111/clr.14445
How many times has this paper been cited?
27 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Clinical Oral Implants Research: sign in and open the PDF from this page.
Who wrote this paper?
X J Fu, Zheng‐Zhen Cai, Junyu Shi, Shichong Qiao, Maurizio S. Tonetti, Hong‐Chang Lai, Bei‐Lei Liu.
What is the DOI of this paper?
10.1111/clr.14445, permanently at https://doi.org/10.1111/clr.14445. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.