Review article · 2023 · Open access
Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies
Medicina, 60(1), 11 · Published 20 December 2023 · DOI 10.3390/medicina60010011
In brief
“Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies” is a 2023 review article by Saurabh Jain and 12 co-authors, published in Medicina. OpenAlex counts 76 citations as of 18 November 2026, which puts it in the top 1% of works published in 2023 by citations. It is open access under a CC BY licence: the full text is free to read at Medicina.
- Citations
- 76
- Most cited in
- 2025 (35)
- Field-weighted impact
- 2.97
- References
- 48
- Authors
- 13
Abstract
Background and Objectives: The present systematic review and meta-analysis undertake a comparison of studies that examine the accuracy of robot-assisted dental implant placement in relation to static computer-assisted implant surgery (SCAIS), dynamic computer-assisted implant surgery (DCAIS), and freehand procedures. This study aims to provide a comprehensive understanding of the precision of robot-assisted dental implant placement and its comparative efficacy in relation to other placement techniques. Methods: The guidelines recommended by Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) were used to organize and compose this review. Four electronic databases (PubMed, Web of Science, Scopus, and Cochrane) were systematically searched for pertinent articles. Articles were selected following the inclusion and exclusion criteria. Qualitative and quantitative analyses of the selected articles were performed. Results: The initial electronic search resulted in 1087 hits. Based on the inclusion and exclusion criteria, five articles were selected for qualitative analysis, out of which three were considered for quantitative analysis. Three parameters were considered for accuracy evaluation (angular, coronal, and apical deviation). The mean angular deviation was −1.22 degrees (95% CI, −1.06–−1.39), the mean coronal deviation was −0.15 mm (95% CI, −0.24–−0.07), and the mean apical deviation was −0.19 mm (95% CI, −0.27–−0.10). Conclusions: The robotic implant system was found to have significantly lower angular deviations and insignificantly lower coronal and apical deviations compared to DCAIS. Within the limitations of this review, it can be concluded that robot-assisted implant placement in resin models permits higher accuracy compared to DCAIS and SCAIS systems. However, due to the limited number of comparative studies with high heterogeneity, the findings of this review should be interpreted with caution. Further research is necessary to confirm the clinical application of robotics in implant surgery.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Jain, S., Sayed, M. E., Ibraheem, W., Ageeli, A. A., Gandhi, S., Jokhadar, H. F., AlResayes, S. S., Alqarni, H., Alshehri, A. H., Huthan, H. M., Alami, A., Al Wadei, M. H. D., & Aljabri, Y. S. (2023). Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies. Medicina, 60(1), 11. https://doi.org/10.3390/medicina60010011
MLA 9
Jain, Saurabh, et al. “Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies.” Medicina, vol. 60, no. 1, 2023, p. 11. https://doi.org/10.3390/medicina60010011.
Chicago
Jain, Saurabh, Mohammed E. Sayed, Wael Ibraheem, Abrar A. Ageeli, Sumir Gandhi, Hossam F. Jokhadar, Saad Saleh AlResayes, et al. 2023. “Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies.” Medicina 60 (1): 11. https://doi.org/10.3390/medicina60010011.
Harvard
Jain, S. et al. (2023) ‘Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies’, Medicina, 60(1), p. 11. doi:10.3390/medicina60010011.
IEEE
S. Jain et al., “Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies,” Medicina, vol. 60, no. 1, p. 11, 2023, doi: 10.3390/medicina60010011.
BibTeX
@article{jain2023accuracy,
title = {{Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies}},
author = {Jain, Saurabh and Sayed, Mohammed E. and Ibraheem, Wael and Ageeli, Abrar A. and Gandhi, Sumir and Jokhadar, Hossam F. and AlResayes, Saad Saleh and Alqarni, Hatem and Alshehri, Abdullah Hasan and Huthan, Halah Mohammed and Alami, Atheer and Al Wadei, Mohammed Hussain Dafer and Aljabri, Yahya Sulaiman},
journal = {Medicina},
year = {2023},
volume = {60},
number = {1},
pages = {11},
doi = {10.3390/medicina60010011},
url = {https://doi.org/10.3390/medicina60010011}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2024 | 12 | |
| 2025 | 35 | |
| 2026 | 29 |
Its field-weighted citation impact is 2.97: it has been cited 2.97 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- computer-assisted implant surgery
- implant placement accuracy
- angular deviation
- coronal deviation
- apical deviation
- freehand implant placement
Work with this paper
Most-cited papers in Dentistry
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionJohn Silness, Harald A. Löe · Acta Odontologica Scandinavica · 1964 · 8,071 citations
- Periodontal Disease in Pregnancy I. Prevalence and SeverityHarald A. Löe, John Silness · Acta Odontologica Scandinavica · 1963 · 7,339 citations
- Microbial complexes in subgingival plaqueS. S. Socransky, Anne D. Haffajee, MaryAnn Cugini and 2 more · Journal Of Clinical Periodontology · 1998 · 5,207 citations
- Development of a Classification System for Periodontal Diseases and ConditionsGary C. Armitage · Annals of Periodontology · 1999 · 5,198 citations
- Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†ERIC L. SCHIFFMAN, Richard K. Ohrbach, Edmond L. Truelove and 27 more · Journal of Oral & Facial Pain and Headache · 2014 · 4,942 citations
Questions about this paper
How do I cite this paper in APA style?
Jain, S., Sayed, M. E., Ibraheem, W., Ageeli, A. A., Gandhi, S., Jokhadar, H. F., AlResayes, S. S., Alqarni, H., Alshehri, A. H., Huthan, H. M., Alami, A., Al Wadei, M. H. D., & Aljabri, Y. S. (2023). Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies. Medicina, 60(1), 11. https://doi.org/10.3390/medicina60010011
How many times has this paper been cited?
76 times, according to OpenAlex on 18 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Medicina: sign in and open the PDF from this page.
Who wrote this paper?
Saurabh Jain, Mohammed E. Sayed, Wael Ibraheem, Abrar A. Ageeli, Sumir Gandhi, Hossam F. Jokhadar, Saad Saleh AlResayes, Hatem Alqarni, Abdullah Hasan Alshehri, Halah Mohammed Huthan, Atheer Alami, Mohammed Hussain Dafer Al Wadei and 1 more.
What is the DOI of this paper?
10.3390/medicina60010011, permanently at https://doi.org/10.3390/medicina60010011. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 18 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.