Journal article · 2021 · Open access

Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs

Maged S. Alhammadi, Abeer Abdulkareem Almashraqi, Rayid Hussain Alnami, Nawaf Mohammad Ashqar, Omar Hassan Alamir, Esam Saleh Halboub, Rodolfo Reda, Luca Testarelli, Shankargouda Patil

Diagnostics, 11(5), 757 · Published 23 April 2021 · DOI 10.3390/diagnostics11050757

Open full textCite this paper

In brief

“Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs” is a 2021 journal article by Maged S. Alhammadi and 8 co-authors, published in Diagnostics. OpenAlex counts 64 citations as of 25 November 2026, which puts it in the top 4% of works published in 2021 by citations. It is open access under a CC BY licence: the full text is free to read at Diagnostics.

Citations
64
Most cited in
2022 (32)
Field-weighted impact
11.81
References
16
Authors
9

Abstract

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18-30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland-Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Alhammadi, M. S., Almashraqi, A. A., Alnami, R. H., Ashqar, N. M., Alamir, O. H., Halboub, E. S., Reda, R., Testarelli, L., & Patil, S. (2021). Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs. Diagnostics, 11(5), 757. https://doi.org/10.3390/diagnostics11050757

MLA 9

Alhammadi, Maged S., et al. “Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs.” Diagnostics, vol. 11, no. 5, 2021, p. 757. https://doi.org/10.3390/diagnostics11050757.

Chicago

Alhammadi, Maged S., Abeer Abdulkareem Almashraqi, Rayid Hussain Alnami, Nawaf Mohammad Ashqar, Omar Hassan Alamir, Esam Saleh Halboub, Rodolfo Reda, Luca Testarelli, and Shankargouda Patil. 2021. “Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs.” Diagnostics 11 (5): 757. https://doi.org/10.3390/diagnostics11050757.

Harvard

Alhammadi, M. S. et al. (2021) ‘Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs’, Diagnostics, 11(5), p. 757. doi:10.3390/diagnostics11050757.

IEEE

M. S. Alhammadi et al., “Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs,” Diagnostics, vol. 11, no. 5, p. 757, 2021, doi: 10.3390/diagnostics11050757.

BibTeX

@article{alhammadi2021accuracy,
  title     = {{Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs}},
  author    = {Alhammadi, Maged S. and Almashraqi, Abeer Abdulkareem and Alnami, Rayid Hussain and Ashqar, Nawaf Mohammad and Alamir, Omar Hassan and Halboub, Esam Saleh and Reda, Rodolfo and Testarelli, Luca and Patil, Shankargouda},
  journal   = {Diagnostics},
  year      = {2021},
  volume    = {11},
  number    = {5},
  pages     = {757},
  doi       = {10.3390/diagnostics11050757},
  url       = {https://doi.org/10.3390/diagnostics11050757}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
20211111
20223232
202388
202444
202555
202644

Its field-weighted citation impact is 11.81: it has been cited 11.81 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Health Sciences › Dentistry › Oral Surgery › Dental Radiography and Imaging

  • facial soft tissue profile
  • cone-beam computed tomography
  • face images
  • measurement accuracy
  • reproducibility
  • mandibular plane angle
  • posterior facial height
  • facial convexity

Work with this paper

Most-cited papers in Dentistry

All highly cited Dentistry papers

Questions about this paper

How do I cite this paper in APA style?

Alhammadi, M. S., Almashraqi, A. A., Alnami, R. H., Ashqar, N. M., Alamir, O. H., Halboub, E. S., Reda, R., Testarelli, L., & Patil, S. (2021). Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs. Diagnostics, 11(5), 757. https://doi.org/10.3390/diagnostics11050757

How many times has this paper been cited?

64 times, according to OpenAlex on 25 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Diagnostics: sign in and open the full text from this page.

Who wrote this paper?

Maged S. Alhammadi, Abeer Abdulkareem Almashraqi, Rayid Hussain Alnami, Nawaf Mohammad Ashqar, Omar Hassan Alamir, Esam Saleh Halboub, Rodolfo Reda, Luca Testarelli, Shankargouda Patil.

What is the DOI of this paper?

10.3390/diagnostics11050757, permanently at https://doi.org/10.3390/diagnostics11050757. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 25 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.