Journal article · 2005 · Open access

A standard curve based method for relative real time PCR data processing

Alexey A. Larionov, Andreas Krause, William R. Miller

BMC Bioinformatics, 6(1), 62 · Published 21 March 2005 · DOI 10.1186/1471-2105-6-62

Open PDFView at the publisherCite this paper

In brief

“A standard curve based method for relative real time PCR data processing” is a 2005 journal article by Alexey A. Larionov and 2 co-authors, published in BMC Bioinformatics. OpenAlex counts 1,091 citations as of 24 November 2026, which puts it in the top 1% of works published in 2005 by citations. It is open access under a CC BY licence: the full text is free to read at BMC Bioinformatics.

Citations
1,091
Most cited in
2021 (85)
Field-weighted impact
5.34
References
22
Authors
3

Abstract

BACKGROUND: Currently real time PCR is the most precise method by which to measure gene expression. The method generates a large amount of raw numerical data and processing may notably influence final results. The data processing is based either on standard curves or on PCR efficiency assessment. At the moment, the PCR efficiency approach is preferred in relative PCR whilst the standard curve is often used for absolute PCR. However, there are no barriers to employ standard curves for relative PCR. This article provides an implementation of the standard curve method and discusses its advantages and limitations in relative real time PCR. RESULTS: We designed a procedure for data processing in relative real time PCR. The procedure completely avoids PCR efficiency assessment, minimizes operator involvement and provides a statistical assessment of intra-assay variation. The procedure includes the following steps. (I) Noise is filtered from raw fluorescence readings by smoothing, baseline subtraction and amplitude normalization. (II) The optimal threshold is selected automatically from regression parameters of the standard curve. (III) Crossing points (CPs) are derived directly from coordinates of points where the threshold line crosses fluorescence plots obtained after the noise filtering. (IV) The means and their variances are calculated for CPs in PCR replicas. (V) The final results are derived from the CPs' means. The CPs' variances are traced to results by the law of error propagation. A detailed description and analysis of this data processing is provided. The limitations associated with the use of parametric statistical methods and amplitude normalization are specifically analyzed and found fit to the routine laboratory practice. Different options are discussed for aggregation of data obtained from multiple reference genes. CONCLUSION: A standard curve based procedure for PCR data processing has been compiled and validated. It illustrates that standard curve design remains a reliable and simple alternative to the PCR-efficiency based calculations in relative real time PCR.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Larionov, A. A., Krause, A., & Miller, W. R. (2005). A standard curve based method for relative real time PCR data processing. BMC Bioinformatics, 6(1), 62. https://doi.org/10.1186/1471-2105-6-62

MLA 9

Larionov, Alexey A., et al. “A standard curve based method for relative real time PCR data processing.” BMC Bioinformatics, vol. 6, no. 1, 2005, p. 62. https://doi.org/10.1186/1471-2105-6-62.

Chicago

Larionov, Alexey A., Andreas Krause, and William R. Miller. 2005. “A standard curve based method for relative real time PCR data processing.” BMC Bioinformatics 6 (1): 62. https://doi.org/10.1186/1471-2105-6-62.

Harvard

Larionov, A. A., Krause, A. and Miller, W. R. (2005) ‘A standard curve based method for relative real time PCR data processing’, BMC Bioinformatics, 6(1), p. 62. doi:10.1186/1471-2105-6-62.

IEEE

A. A. Larionov, A. Krause, and W. R. Miller, “A standard curve based method for relative real time PCR data processing,” BMC Bioinformatics, vol. 6, no. 1, p. 62, 2005, doi: 10.1186/1471-2105-6-62.

BibTeX

@article{larionov2005standard,
  title     = {{A standard curve based method for relative real time PCR data processing}},
  author    = {Larionov, Alexey A. and Krause, Andreas and Miller, William R.},
  journal   = {BMC Bioinformatics},
  year      = {2005},
  volume    = {6},
  number    = {1},
  pages     = {62},
  doi       = {10.1186/1471-2105-6-62},
  url       = {https://doi.org/10.1186/1471-2105-6-62}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
20176969
20187373
20196464
20205353
20218585
20224949
20233535
20244949
20254747
20262727

Its field-weighted citation impact is 5.34: it has been cited 5.34 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications

  • calibration curve
  • PCR efficiency
  • gene expression quantification
  • crossing points
  • baseline correction
  • amplitude normalization
  • noise reduction
  • error propagation

Work with this paper

Most-cited papers in Biochemistry, Genetics and Molecular Biology

All highly cited Biochemistry, Genetics and Molecular Biology papers

Questions about this paper

How do I cite this paper in APA style?

Larionov, A. A., Krause, A., & Miller, W. R. (2005). A standard curve based method for relative real time PCR data processing. BMC Bioinformatics, 6(1), 62. https://doi.org/10.1186/1471-2105-6-62

How many times has this paper been cited?

1,091 times, according to OpenAlex on 24 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at BMC Bioinformatics: sign in and open the PDF from this page.

Who wrote this paper?

Alexey A. Larionov, Andreas Krause, William R. Miller.

What is the DOI of this paper?

10.1186/1471-2105-6-62, permanently at https://doi.org/10.1186/1471-2105-6-62. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 24 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.