Conference paper · 2020
A Novel Soft Robotic Glove with Positive-negative Pneumatic Actuator for Hand Rehabilitation
IEEE/ASME International Conference on Advanced Intelligent Mechatronics, 1840–1847 · Published 1 July 2020 · DOI 10.1109/aim43001.2020.9158826
In brief
“A Novel Soft Robotic Glove with Positive-negative Pneumatic Actuator for Hand Rehabilitation” is a 2020 conference paper by HU De-bin and 5 co-authors, published in IEEE/ASME International Conference on Advanced Intelligent Mechatronics. OpenAlex counts 52 citations as of 22 November 2026, which puts it in the top 8% of works published in 2020 by citations. The publisher's version is not open access, and OpenAlex records no free legal copy.
- Citations
- 52
- Most cited in
- 2024 (15)
- Field-weighted impact
- 5.37
- References
- 28
- Authors
- 6
Abstract
Pneumatic soft robots show great potential application value in the field of hand rehabilitation. This paper presents a novel pneumatic soft robotic glove for hand rehabilitation with a portable pneumatic box. The glove uses positive-negative pneumatic actuator made of bellows, which is very light (only 149g), easy to wear, comfortable, customizable, safe, easy to make… Read the full abstract at the publisher.
Excerpt. This paper is not open access.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
De-bin, H., Zhang, J., Yang, Y., Li, Q., Li, D., & Hong, J. (2020). A Novel Soft Robotic Glove with Positive-negative Pneumatic Actuator for Hand Rehabilitation. IEEE/ASME International Conference on Advanced Intelligent Mechatronics, 1840–1847. https://doi.org/10.1109/aim43001.2020.9158826
MLA 9
De-bin, HU, et al. “A Novel Soft Robotic Glove with Positive-negative Pneumatic Actuator for Hand Rehabilitation.” IEEE/ASME International Conference on Advanced Intelligent Mechatronics, 2020, pp. 1840–1847. https://doi.org/10.1109/aim43001.2020.9158826.
Chicago
De-bin, HU, Jinhua Zhang, Yuhan Yang, Qiuyang Li, Dahai Li, and Jun Hong. 2020. “A Novel Soft Robotic Glove with Positive-negative Pneumatic Actuator for Hand Rehabilitation.” IEEE/ASME International Conference on Advanced Intelligent Mechatronics: 1840–1847. https://doi.org/10.1109/aim43001.2020.9158826.
Harvard
De-bin, H. et al. (2020) ‘A Novel Soft Robotic Glove with Positive-negative Pneumatic Actuator for Hand Rehabilitation’, IEEE/ASME International Conference on Advanced Intelligent Mechatronics, pp. 1840–1847. doi:10.1109/aim43001.2020.9158826.
IEEE
H. De-bin, J. Zhang, Y. Yang, Q. Li, D. Li, and J. Hong, “A Novel Soft Robotic Glove with Positive-negative Pneumatic Actuator for Hand Rehabilitation,” IEEE/ASME International Conference on Advanced Intelligent Mechatronics, pp. 1840–1847, 2020, doi: 10.1109/aim43001.2020.9158826.
BibTeX
@inproceedings{debin2020novel,
title = {{A Novel Soft Robotic Glove with Positive-negative Pneumatic Actuator for Hand Rehabilitation}},
author = {De-bin, HU and Zhang, Jinhua and Yang, Yuhan and Li, Qiuyang and Li, Dahai and Hong, Jun},
booktitle = {IEEE/ASME International Conference on Advanced Intelligent Mechatronics},
year = {2020},
pages = {1840--1847},
doi = {10.1109/aim43001.2020.9158826},
url = {https://doi.org/10.1109/aim43001.2020.9158826}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2021 | 2 | |
| 2022 | 6 | |
| 2023 | 8 | |
| 2024 | 15 | |
| 2025 | 13 | |
| 2026 | 8 |
Its field-weighted citation impact is 5.37: it has been cited 5.37 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- soft robotic glove
- hand rehabilitation
- pneumatic actuators
- bellows actuator
- finger flexion and extension
- rehabilitation training
Work with this paper
Most-cited papers in Engineering
- A Closed‐form Equation for Predicting the Hydraulic Conductivity of Unsaturated SoilsMartinus Th. van Genuchten · Soil Science Society of America Journal · 1980 · 28,197 citations
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsW. C. Oliver, George M. Pharr · Journal of materials research/Pratt's guide to venture capital sources · 1992 · 27,379 citations
- Digital communicationsOwen Bishop · Routledge eBooks · 2007 · 24,890 citations
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisNorden Eh Huang, Zhengwei Shen, Steven R. Long and 6 more · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 1998 · 24,008 citations
- Numerical Heat Transfer and Fluid FlowSuhas V. Patankar · CRC Press eBooks · 2018 · 23,491 citations
Questions about this paper
How do I cite this paper in APA style?
De-bin, H., Zhang, J., Yang, Y., Li, Q., Li, D., & Hong, J. (2020). A Novel Soft Robotic Glove with Positive-negative Pneumatic Actuator for Hand Rehabilitation. IEEE/ASME International Conference on Advanced Intelligent Mechatronics, 1840–1847. https://doi.org/10.1109/aim43001.2020.9158826
How many times has this paper been cited?
52 times, according to OpenAlex on 22 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
OpenAlex records no free legal copy. Check your library's access, the authors' pages or a repository, or ask the corresponding author for a copy.
Who wrote this paper?
HU De-bin, Jinhua Zhang, Yuhan Yang, Qiuyang Li, Dahai Li, Jun Hong.
What is the DOI of this paper?
10.1109/aim43001.2020.9158826, permanently at https://doi.org/10.1109/aim43001.2020.9158826. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 22 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.