“A coupled hydromechanical fault model for the study of the integrity and safety of geological storage of CO2” is a 2011 journal article by Ariane Ducellier and 2 co-authors, published in Energy Procedia. OpenAlex counts 13 citations as of 21 November 2026. It is open access under a CC BY-NC-ND licence: the full text is free to read at Energy Procedia.
- Citations
- 13
- Most cited in
- 2015 (3)
- Field-weighted impact
- 1.36
- References
- 12
- Authors
- 3
Abstract
The safety study of a CO2 storage site requires the evaluation of the sustainable injection pressure. The faults are generally considered as one of the potential leakage paths as a fault zone could be more permeable than the neighbouring rock matrix. The pressure build up in the reservoir due to the injection procedure changes the stress field within the reservoir and its surrounding rocks. The decrease of effective stress in the vicinity of a fault, due to this pore pressure increase, may lead to fault failure, increasing its permeability or even creating induced seismicity. The aim of this study is to carry out large-scale 2D coupled hydromechanical simulations of the fault behaviour during and after the injection and to study the sensibility of the fault response regarding to some parameters.
Cite this paper
Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.
APA 7
Ducellier, A., Seyedi, D. M., & Foerster, E. (2011). A coupled hydromechanical fault model for the study of the integrity and safety of geological storage of CO2. Energy Procedia, 4, 5138–5145. https://doi.org/10.1016/j.egypro.2011.02.490
MLA 9
Ducellier, Ariane, et al. “A coupled hydromechanical fault model for the study of the integrity and safety of geological storage of CO2.” Energy Procedia, vol. 4, 2011, pp. 5138–5145. https://doi.org/10.1016/j.egypro.2011.02.490.
Chicago
Ducellier, Ariane, Darius M. Seyedi, and Evelyne Foerster. 2011. “A coupled hydromechanical fault model for the study of the integrity and safety of geological storage of CO2.” Energy Procedia 4: 5138–5145. https://doi.org/10.1016/j.egypro.2011.02.490.
Harvard
Ducellier, A., Seyedi, D. M. and Foerster, E. (2011) ‘A coupled hydromechanical fault model for the study of the integrity and safety of geological storage of CO2’, Energy Procedia, 4, pp. 5138–5145. doi:10.1016/j.egypro.2011.02.490.
IEEE
A. Ducellier, D. M. Seyedi, and E. Foerster, “A coupled hydromechanical fault model for the study of the integrity and safety of geological storage of CO2,” Energy Procedia, vol. 4, pp. 5138–5145, 2011, doi: 10.1016/j.egypro.2011.02.490.
BibTeX
@article{ducellier2011coupled,
title = {{A coupled hydromechanical fault model for the study of the integrity and safety of geological storage of CO2}},
author = {Ducellier, Ariane and Seyedi, Darius M. and Foerster, Evelyne},
journal = {Energy Procedia},
year = {2011},
volume = {4},
pages = {5138--5145},
doi = {10.1016/j.egypro.2011.02.490},
url = {https://doi.org/10.1016/j.egypro.2011.02.490}
}
Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)
Citations by year
| Year | Citations | Share of the best year |
|---|---|---|
| 2012 | 1 | |
| 2014 | 1 | |
| 2015 | 3 | |
| 2016 | 1 | |
| 2019 | 1 | |
| 2021 | 1 | |
| 2024 | 1 | |
| 2025 | 3 | |
| 2026 | 1 |
Its field-weighted citation impact is 1.36: it has been cited 1.36 times as often as the average work of the same field, type and year (1.00 is the world average).
Topic and keywords
Physical Sciences › Environmental Science › Environmental Engineering › CO2 Sequestration and Geologic Interactions
- CO2 geological storage
- fault zone permeability
- fault failure
- induced seismicity
- effective stress
- CO2 leakage
- 2D simulation
Work with this paper
Most-cited papers in Environmental Science
- Biodiversity hotspots for conservation prioritiesNorman Myers, Russell A. Mittermeier, Cristina Goettsch Mittermeier and 2 more · Nature · 2000 · 32,720 citations
- The Tragedy of the CommonsGarrett Hardin · Science · 1968 · 26,194 citations
- River flow forecasting through conceptual models part I — A discussion of principlesJ.E. Nash, John V. Sutcliffe · Journal of Hydrology · 1970 · 24,625 citations
- The value of the world's ecosystem services and natural capitalRobert Costanza, Ralph C. d’Arge, R.S. de Groot and 10 more · Nature · 1997 · 23,508 citations
- Climate change 2007: the physical science basisSusan Solomon, Dahe Qin, Martin Manning and 5 more · 2007 · 23,383 citations
Questions about this paper
How do I cite this paper in APA style?
Ducellier, A., Seyedi, D. M., & Foerster, E. (2011). A coupled hydromechanical fault model for the study of the integrity and safety of geological storage of CO2. Energy Procedia, 4, 5138–5145. https://doi.org/10.1016/j.egypro.2011.02.490
How many times has this paper been cited?
13 times, according to OpenAlex on 21 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.
Is this paper free to read?
Yes. It is open access at Energy Procedia: sign in and open the PDF from this page.
Who wrote this paper?
Ariane Ducellier, Darius M. Seyedi, Evelyne Foerster.
What is the DOI of this paper?
10.1016/j.egypro.2011.02.490, permanently at https://doi.org/10.1016/j.egypro.2011.02.490. Sign in and open it from this page.
Bibliographic data from OpenAlex (CC0), last checked 21 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.