“A comparison of PCA and MAF for ToF‐SIMS image interpretation” is a 2009 journal article by Alex Henderson and 2 co-authors, published in Surface and Interface Analysis. OpenAlex counts 70 citations as of 24 November 2026, which puts it in the top 8% of works published in 2009 by citations. It is open access under a CC BY licence: the full text is free to read at Research Explorer (The University of Manchester).

Citations
70
Most cited in
2019 (5)
Field-weighted impact
2.67
References
22
Authors
3

Abstract

While time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) image generation has been useful in the determination of the spatial distribution of chemistry in a broad application area, the amount of secondary ion signal available in each pixel remains small, hampering the use of multivariate analysis (MVA) approaches. The pre‐treatment of data commonly comprises two approaches to increase pixel signal intensity prior to MVA: mass channel summation and pixel summation. Recent advances in instrumentation have lead to much greater signal per image pixel such that a true spectrum can be discerned at each point across the sample. In this study, we determine the outcomes of these two pre‐treatments prior to principal components analysis (PCA) and maximum autocorrelation factor (MAF) analysis in comparison with high signal intensity data. Both PCA and MAF analyses of the high signal intensity data are presented with MAF being identified as the most effective approach. Image data was reduced in intensity to determine the effectiveness of MVA with lower spectral intensity. MAF was found to outperform PCA on such data, although both techniques were useful in the identification of the chemistry present. The data were then mass summed, using a number of different approaches, to reduce mass resolution, leading to a detrimental effect on PCA analysis, but little discernable change to MAF output. Reducing the spatial resolution by summing spectra from adjacent pixels, however, lead to a severe blurring of the MAF image structure, with PCA performing well. Conclusions and recommendation for pre‐treatment and MVA technique selection are presented. Copyright © 2009 John Wiley & Sons, Ltd.

Cite this paper

Formatted from the catalogue record. Check names, capitals and page numbers against the paper before you submit.

APA 7

Henderson, A., Fletcher, J. S., & Vickerman, J. C. (2009). A comparison of PCA and MAF for ToF‐SIMS image interpretation. Surface and Interface Analysis, 41(8), 666–674. https://doi.org/10.1002/sia.3084

MLA 9

Henderson, Alex, et al. “A comparison of PCA and MAF for ToF‐SIMS image interpretation.” Surface and Interface Analysis, vol. 41, no. 8, 2009, pp. 666–674. https://doi.org/10.1002/sia.3084.

Chicago

Henderson, Alex, John S. Fletcher, and John C. Vickerman. 2009. “A comparison of PCA and MAF for ToF‐SIMS image interpretation.” Surface and Interface Analysis 41 (8): 666–674. https://doi.org/10.1002/sia.3084.

Harvard

Henderson, A., Fletcher, J. S. and Vickerman, J. C. (2009) ‘A comparison of PCA and MAF for ToF‐SIMS image interpretation’, Surface and Interface Analysis, 41(8), pp. 666–674. doi:10.1002/sia.3084.

IEEE

A. Henderson, J. S. Fletcher, and J. C. Vickerman, “A comparison of PCA and MAF for ToF‐SIMS image interpretation,” Surface and Interface Analysis, vol. 41, no. 8, pp. 666–674, 2009, doi: 10.1002/sia.3084.

BibTeX

@article{henderson2009comparison,
  title     = {{A comparison of PCA and MAF for ToF‐SIMS image interpretation}},
  author    = {Henderson, Alex and Fletcher, John S. and Vickerman, John C.},
  journal   = {Surface and Interface Analysis},
  year      = {2009},
  volume    = {41},
  number    = {8},
  pages     = {666--674},
  doi       = {10.1002/sia.3084},
  url       = {https://doi.org/10.1002/sia.3084}
}

Download for a reference manager: BibTeX (.bib) · RIS for Zotero, Mendeley and EndNote (.ris)

Citations by year

YearCitationsShare of the best year
201633
201733
201822
201955
202055
202233
202333
202444
202544
202633

Its field-weighted citation impact is 2.67: it has been cited 2.67 times as often as the average work of the same field, type and year (1.00 is the world average).

Topic and keywords

Physical Sciences › Materials Science › Surfaces, Coatings and Films › Ion-surface interactions and analysis

  • ToF-SIMS imaging
  • principal component analysis
  • multivariate analysis
  • spectral intensity
  • mass resolution
  • spatial resolution
  • image interpretation

Work with this paper

Most-cited papers in Materials Science

All highly cited Materials Science papers

Questions about this paper

How do I cite this paper in APA style?

Henderson, A., Fletcher, J. S., & Vickerman, J. C. (2009). A comparison of PCA and MAF for ToF‐SIMS image interpretation. Surface and Interface Analysis, 41(8), 666–674. https://doi.org/10.1002/sia.3084

How many times has this paper been cited?

70 times, according to OpenAlex on 24 November 2026. Google Scholar and Scopus count different sets of sources, so their numbers differ.

Is this paper free to read?

Yes. It is open access at Research Explorer (The University of Manchester): sign in and open the full text from this page.

Who wrote this paper?

Alex Henderson, John S. Fletcher, John C. Vickerman.

What is the DOI of this paper?

10.1002/sia.3084, permanently at https://doi.org/10.1002/sia.3084. Sign in and open it from this page.

Bibliographic data from OpenAlex (CC0), last checked 24 November 2026. ResearchGuru does not host this paper; once you are signed in, the links open it at the publisher or the repository that does.